The DOI matches its Crossref record.
The GSC Sensitive High Resolution Ion Microprobe (SHRIMP): analytical techniques of zircon U-Th-Pb age determinations and performance evaluation
Abstract
Analytical methods of zircon U-Pb-Th age determinations using the newly acquired Sensitive High Resolution Ion Microprobe (SHRIMP) have been established and are reported in detail. In a SHRIMP analysis, an attempt is made to sample the smallest possible amount of zircon that can give useful age information, usually a spot selectively variable from about 5 to 30 µm diameter and <1 µm deep. Only 1-10 ng of zircon is sampled, three orders of magnitude smaller than a typical isotope dilution thermal ionization mass spectrometry (ID-TIMS) analysis. Causes and mitigation of the variable relative yields of Pb, U, and Th due to the sputtering process are discussed. Megacrystic zircon from the Kipawa syenite complex has been adopted as the current Pb/U and Pb/Th standard; the Pb/U age of the standard has been independently determined by ID-TIMS analysis at 993.4 ± 0.7 Ma. SHRIMP data reduction and error propogation procedures are summarized. The overall performance of the SHRIMP was evaluated by analyzing zircons of varying ages (0.5 to 2.7 Ga) using the new zircon standard to calibrate the Pb/U and Pb/Th ratios. Both 207Pb/206Pb and 206Pb/238U ages agree within error with the ID-TIMS ages. The 208Pb/232Th are systematically younger and indicate unknown analytical problems. Under routine conditions, 2s age uncertainties for single spots in average zircons decrease from typically ±4% at 0.5-1.5 Ga, to ±2% at 1.9 Ga, and ±0.5% at 2.7 Ga. The 2s errors on pooled analyses of relatively simple zircon samples decrease from ±1.5% at 0.5-1.5 Ga, ±0.5% at 1.9 Ga, and ±0.2% at 2.7 Ga. For zircons <1.5 Ga, precise age determinations rely mainly on pooling of 206Pb/238U ratios or regression on a Tera-Wasserberg diagram, whereas for zircons >1.5 Ga, ages are derived mainly from the pooled 207Pb/206Pb ratios of concordant zircons. As a rule of thumb, it is generally possible to derive a SHRIMP zircon age that has an error of about five times that of a precise ID-TIMS analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kröner, A., Wilde, S. A., Zhao, G. C., O’Brien, P. J., Sun, M., Liu, D. Y., Wan, Y. S., Liu, S. W., & Guo, J. H. (2006) · Precambrian Research · doi:10.1016/j.precamres.2006.01.008 · Cited by 431
Measurement of SIMS Instrumental Mass Fractionation of Pb Isotopes During Zircon Dating
Stern, R. A., Bodorkos, S., Kamo, S. L., Hickman, A. H., & Corfu, F. (2009) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2009.00023.x · Cited by 405
Self-citationA Hadean to Paleoarchean geodynamo recorded by single zircon crystals
Tarduno, J. A., Cottrell, R. D., Davis, W. J., Nimmo, F., & Bono, R. K. (2015) · Science · doi:10.1126/science.aaa9114 · Cited by 269
St‐Onge, M. R., Rayner, N., Palin, R. M., Searle, M. P., & Waters, D. J. (2013) · Journal of Metamorphic Geology · doi:10.1111/jmg.12030 · Cited by 160
Metadata
- Authors
- Stern, R. A.
- Published
- 1997
- OpenAlex
- W2909223431
- Cited by
- 274
- References
- 0
- Type
- report
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The GSC Sensitive High Resolution Ion Microprobe (SHRIMP): analytical techniques of zircon U-Th-Pb age determinations and performance evaluation. https://app.cochat.ai/papers/10.4095/209089
- The paper
- Stern, R. A. (1997). The GSC Sensitive High Resolution Ion Microprobe (SHRIMP): analytical techniques of zircon U-Th-Pb age determinations and performance evaluation. https://doi.org/10.4095/209089
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.