Sen, S, Laha, TK, Patnaik, RK·2008·Indian Journal of Pharmaceutical Sciences

Abstract

A rapid and sensitive reverse phase high performance liquid chromatographic method is depicted for the qualitative and quantitative assay of letrozole in pharmaceutical dosage forms. Letrozole was chromatographed on a reverse phase C18 column with a mobile phase consisting of acetonitrile and phosphate buffer (pH 7.8) in the ratio of 70:30 v/v. The mobile phase was pumped at a flow rate of 1 ml/min. Acenaphthene was used as an internal standard and the eluents were monitored at 232 nm. The retention time of the drug was 3.385 min. With this method, linearity was observed in the range of 10-100 mug/ml. The LOD and LOQ were found to be 0.51 mug/ml and 1.52 mug/ml, respectively. The method was found to be applicable for analysis of drug in tablets. The results of the analysis were validated statistically.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4103/0250-474x.43019

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 4

  1. [1]Barrows LR Gennaro AR Antineoplastic and immunoactive drugs Remington: The Science and Practice of Pharmacy 2000 Vol II 20th ed Philadelphia, PA Lippincott Williams and Wilkins Company 1477 506
  2. [2]Lamb HM Adkins JC Letrozole: A review of its use in postmenopausal women with advanced breast cancer Drugs 1998 56 6 1125 40 9878997
  3. [4]Mouridsen H Gershanovich M Sun Y Superior efficacy of Letrozole versus Tamoxifen as first line therapy for postmenopausal women with advanced breast cancer J Clin Oncol 2001 19 10 2596 606 11352951
  4. [6]Itoh T Karlsberg K Kijima I Yuan YC Smith D Letrozole: A microarray Approach Mol Cancer Res 2005 3 4 203 18 15831674

Cited by

Sorted by citations

Authors
Sen, S., Laha, T., & Patnaik, R.
Corresponding author
Sen, S
Venue
Indian Journal of Pharmaceutical Sciences
Published
2008
Volume
70
Issue
3
Pages
401
ISSN
0250-474X (ISSN-L)
OpenAlex
W2084069543
Cited by
17
References
0
Citations by year
2025: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 1 · 2015: 2 · 2013: 2 · 2012: 3
FWCI
0.34
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Indian Journal of Pharmaceutical Sciences (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
Keywords
letrozole, reversed-phase HPLC, pharmaceutical dosage forms, tablets, method validation, C18 column

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review