The KIDROP model of combining strategies for providing retinopathy of prematurity screening in underserved areas in India using wide-field imaging, tele-medicine, non-physician graders and smart phone reporting
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
AIM: To report the Karnataka Internet Assisted Diagnosis of Retinopathy of Prematurity (KIDROP) program for retinopathy of prematurity (ROP) screening in underserved rural areas using an indigenously developed tele-ROP model. MATERIALS AND METHODS: KIDROP currently provides ROP screening and treatment services in three zones and 81 neonatal units in Karnataka, India. Technicians were trained to use a portable Retcam Shuttle (Clarity, USA) and validated against ROP experts performing indirect ophthalmoscopy. An indigenously developed 20-point score (STAT score) graded their ability (Level I to III) to image and decide follow-up based on a three-way algorithm. Images were also uploaded on a secure tele-ROP platform and accessed and reported by remote experts on their smart phones (iPhone, Apple). RESULTS: 6339 imaging sessions of 1601 infants were analyzed. A level III technician agreed with 94.3% of all expert decisions. The sensitivity, specificity, positive predictive value and negative predictive value for treatment grade disease were 95.7, 93.2, 81.5 and 98.6 respectively. The kappa for technicians to decide discharge of babies was 0.94 (P < 0.001). Only 0.4% of infants needing treatment were missed.The kappa agreement of experts reporting on the iPhone vs. Retcam for treatment requiring and mild ROP were 0.96 and 0.94 (P < 0.001) respectively. CONCLUSIONS: This is the first and largest real-world program to employ accredited non-physicians to grade and report ROP. The KIDROP tele-ROP model demonstrates that ROP services can be delivered to the outreach despite lack of specialists and may be useful in other middle-income countries with similar demographics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The International Classification of Retinopathy of Prematurity Revisited
(2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.7.991 · Cited by 2,932
(2003) · Archives of Ophthalmology · doi:10.1001/archopht.121.12.1684 · Cited by 1,679
Retinopathy of prematurity in middle-income countries
Gilbert, C., Rahi, J., Eckstein, M., O'Sullivan, J., & Foster, A. (1997) · The Lancet · doi:10.1016/s0140-6736(97)01107-0 · Cited by 471
Self-citationSchwartz, S. D., Harrison, S. A., Ferrone, P. J., & Trese, M. T. (2000) · Ophthalmology · doi:10.1016/s0161-6420(99)00003-2 · Cited by 178
Telemedical Retinopathy of Prematurity Diagnosis: Accuracy, Reliability, and Image Quality
Chiang, M. F. (2007) · Archives of Ophthalmology · doi:10.1001/archopht.125.11.1531 · Cited by 176 · cited 1×
“[2,32] In most ‘real-world’ programs, [2] images captured by nurses, [33-37] ophthalmic photographers [38-41] or ophthalmologists [42-45] are read onsite or remotely by ‘ROP experts’ using a direct, ‘store and forward’ or image transfer platforms within a de fi ned time period which could vary from…”
BackgroundTelemedicine for Retinopathy of Prematurity Diagnosis: Evaluation and Challenges
Richter, G. M., Williams, S. L., Starren, J. B., Flynn, J. T., & Chiang, M. F. (2009) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2009.02.020 · Cited by 132 · cited 1×
“[2,32] In most ‘real-world’ programs, [2] images captured by nurses, [33-37] ophthalmic photographers [38-41] or ophthalmologists [42-45] are read onsite or remotely by ‘ROP experts’ using a direct, ‘store and forward’ or image transfer platforms within a de fi ned time period which could vary from…”
BackgroundAccuracy and Reliability of Remote Retinopathy of Prematurity Diagnosis
Chiang, M. F., Keenan, J. D., Starren, J. B., Du, Y. E., Schiff, W. M., Barile, G. R., Li, J., Johnson, R. A., Hess, D. J., & Flynn, J. T. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.3.322 · Cited by 128 · cited 1×
“[2,32] In most ‘real-world’ programs, [2] images captured by nurses, [33-37] ophthalmic photographers [38-41] or ophthalmologists [42-45] are read onsite or remotely by ‘ROP experts’ using a direct, ‘store and forward’ or image transfer platforms within a de fi ned time period which could vary from…”
BackgroundScreening for retinopathy of prematurity employing the retcam 120: sensitivity and specificity.
Roth, D. B., Morales, D. S., Feuer, W. J., Hess, D. J., Johnson, R. A., & Flynn, J. T. (2001) · PubMed · Cited by 118
Programme planning and screening strategy in retinopathy of prematurity.
Jalali, S., Anand, R. K., Kumar, H., et al. (2003) · PubMed · Cited by 106
Telemedical Diagnosis of Retinopathy of Prematurity
Scott, K. E., Kim, D. Y., Wang, L., Kane, S., Coki, O., Starren, J. B., Flynn, J. T., & Chiang, M. F. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.09.006 · Cited by 103 · cited 1×
“[35] The ability of images to document, review, store and compare disease far outweighs routine indirect ophthalmoscopy, even when performed by an expert.”
BackgroundChiang, M. F., Starren, J., Du, Y. E., Keenan, J. D., Schiff, W. M., Barile, G. R., Li, J., Johnson, R. A., Hess, D. J., & Flynn, J. T. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2006.091900 · Cited by 75 · cited 1×
“photographers[38-41] or ophthalmologists[42-45] are read onsite or remotely by ‘ROP experts’ using a direct, ‘store and forward’ or image transfer platforms within a defi ned time period which could vary from a day to a week.”
BackgroundGolnik, C., Beaver, H. A., Gauba, V., Lee, A. G., Mayorga, E., Palis, A. G., & Saleh, G. M. (2013) · Europe PMC (PubMed Central) · Cited by 72
Murakami, Y., Jain, A., Silva, R. A., Lad, E. M., Gandhi, J. K., & Moshfeghi, D. M. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.138867 · Cited by 63 · cited 2×
“…programs’ [46] from Canada, [42] United States, [34] and Germany [43] have used trained ophthalmologists or experts to remotely read and interpret images with di ff erent terminologies such as referral warranted ROP (RW-ROP) [42] or clinically signi fi cant ROP (CS-ROP) [34] for decision algorithms.”
BackgroundWhat Is the Real Gold Standard for ROP Screening?
Trese, M. T. (2008) · Retina · doi:10.1097/iae.0b013e31816a5587 · Cited by 52 · cited 1×
“[48] Studies suggest that photographic documentation may ‘inadvertently’ detect mild disease that was ‘missed’ on ophthalmoscopic examination.”
Background
Cited by
Sondaal, S. F. V., Browne, J. L., Amoakoh-Coleman, M., Borgstein, A., Miltenburg, A. S., Verwijs, M., & Klipstein-Grobusch, K. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154664 · Cited by 441
“These included interventions aimed at family planning [55,56], programs for immunization beyond 28 days [57,58], retinopathy of immaturity [59], and breastfeeding practices [48].”
BackgroundRetinopathy of prematurity: Past, present and future
Shah, P. K. (2016) · World Journal of Clinical Pediatrics · doi:10.5409/wjcp.v5.i1.35 · Cited by 207
Clinical photography in dermatology using smartphones: An overview
Ashique, K., Kaliyadan, F., & Aurangabadkar, S. (2015) · Indian Dermatology Online Journal · doi:10.4103/2229-5178.156381 · Cited by 61
“[1] A number of smartphone applications that offer valuable clinical utility are now available.[2,3] The ease of capturing and sharing images with a smartphone makes it useful in clinical photography.”
Background
Metadata
- Authors
- Vinekar, A., Gilbert, C., Dogra, M., Kurian, M., Shainesh, G., Shetty, B., & Bauer, N.
- Venue
- Indian Journal of Ophthalmology
- Publisher
- Medknow
- Published
- 2014
- Volume
- 62
- Issue
- 1
- Pages
- 41
- ISSN
- 0301-4738 (ISSN-L)
- OpenAlex
- W2039517476
- Cited by
- 219
- References
- 14
- FWCI
- 16.11
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.