The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Impact of the COVID-19 lockdown on digital device-related ocular health
Open accessAbstract
PURPOSE: Since the declaration of the lockdown due to COVID-19, the usage of digital devices has gone up across the globe, resulting in a challenge for the visual systems of all ages. The purpose of this study is to assess the impact of the lockdown on digital device usage, and consequently, the ocular surface health implications and circadian rhythm abnormalities related to digital eye strain. METHODS: An open online survey was sent through various social media platforms and was open for a period of 2 weeks. RESULTS: A total of 407 usable responses were obtained; the average age of respondents was 27.4 years. Typically, 93.6% of respondents reported an increase in their screen time since the lockdown was declared. The average increase in digital device usage was calculated at about 4.8 ± 2.8 h per day. The total usage per day was found to be 8.65 ± 3.74 hours. Sleep disturbances have been reported by 62.4% of people. Typically, 95.8% of respondents had experienced at least one symptom related to digital device usage, and 56.5% said that the frequency and intensity of these symptoms increased since the lockdown was declared. CONCLUSION: The study highlighted the drastic increase in use of digital devices after the initiation of the COVID-19 lockdown, and along with it, the slow deterioration of ocular health across all age groups. Awareness about prevention of digital eye strain should be stressed, and going forward, measures to bring these adverse effects to a minimum should be explored.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chang, A.-M., Aeschbach, D., Duffy, J. F., & Czeisler, C. A. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1418490112 · Cited by 1,430 · cited 1×
“[1] Prolonged usage of these devices is not only a stressor on the visual system but also causes musculoskeletal strain[2-4] and circadian disturbances,[2,5,6] and these make up the umbrella diagnosis of computer vision syndrome (though the terms digital eye strain and computer vision syndrome are often used interchan…”
Background
Cited by
Pandya, A., & Lodha, P. (2021) · Frontiers in Human Dynamics · doi:10.3389/fhumd.2021.684137 · Cited by 371
Digital Eye Strain- A Comprehensive Review
Kaur, K., Gurnani, B., Nayak, S., Deori, N., Kaur, S., Jethani, J., Singh, D., Agarkar, S., Hussaindeen, J. R., Sukhija, J., et al. (2022) · Ophthalmology and Therapy · doi:10.1007/s40123-022-00540-9 · Cited by 313
Metadata
- Authors
- Bahkir, F., & Grandee, S.
- Venue
- Indian Journal of Ophthalmology
- Publisher
- Medknow
- Published
- 2020
- Volume
- 68
- Issue
- 11
- Pages
- 2378
- ISSN
- 0301-4738 (ISSN-L)
- OpenAlex
- W3096733916
- Cited by
- 211
- References
- 1
- FWCI
- 42.30
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of the COVID-19 lockdown on digital device-related ocular health. https://app.cochat.ai/papers/10.4103/ijo.ijo_2306_20
- The paper
- Bahkir, F., & Grandee, S. (2020). Impact of the COVID-19 lockdown on digital device-related ocular health. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_2306_20
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.