Cited by 34Analytical Methods in PharmaceuticalsBiosimilars and Bioanalytical MethodsStatistical Methods in Clinical Trials

Utilization of Data Below the Analytical Limit of Quantitation in Pharmacokinetic Analysis and Modeling: Promoting Interdisciplinary Debate

Hecht, Max, Veigure, Rūta, Couchman, Lewis, S Barker, Charlotte I, Standing, Joseph F, Takkis, Kalev, Evard, Hanno, Johnston, Atholl +3 more·2018·Bioanalysis

Abstract

Traditionally, bioanalytical laboratories do not report actual concentrations for samples with results below the LOQ (BLQ) in pharmacokinetic studies. BLQ values are outside the method calibration range established during validation and no data are available to support the reliability of these values. However, ignoring BLQ data can contribute to bias and imprecision in model-based pharmacokinetic analyses. From this perspective, routine use of BLQ data would be advantageous. We would like to initiate an interdisciplinary debate on this important topic by summarizing the current concepts and use of BLQ data by regulators, pharmacometricians and bioanalysts. Through introducing the limit of detection and evaluating its variability, BLQ data could be released and utilized appropriately for pharmacokinetic research.

Integrity signals

Registry

Crossref · 10.4155/bio-2018-0078

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Concentration data below LOQ but not below LOD were included to evaluate the excretion profile because inclusion can result in a better fit and excluding or replacing them with zero could lead to biased pharmacokinetic parameters.

    “Concentration data below the LOQ (but not below the LOD) were included to evaluate the excretion profile, as their inclusion can result in a better fit of the excretion profile model, while excluding or replacing them with zero could lead to biased pharmacokinetic parameters [39,40,41,42].”

The citation lists haven’t been fetched yet

References 252 · Cited by 34

Authors
Hecht, M., Veigure, R., Couchman, L., S Barker, C. I., Standing, J. F., Takkis, K., Evard, H., Johnston, A., Herodes, K., Leito, I., & Kipper, K.
Affiliations
  • St George's, University of London (GB)
  • Chair of Analytical Chemistry, Institute of Chemistry, University of Tartu, 14a Ravila Street, 50411Tartu, Estonia
  • Paediatric Infectious Diseases Research Group, Institute for Infection & Immunity, St George's University of London, London, SW17 0RE, UK
  • University of Tartu (EE)
Venue
Bioanalysis
Published
2018-07-23
Volume
10
Issue
15
Pages
1229-1248
ISSN
  • 1757-6180 (ISSN-L)
  • 1757-6199
OpenAlex
W2883148506
Cited by
34
References
252
Citations by year
2026: 3 · 2025: 4 · 2024: 7 · 2023: 1 · 2022: 5 · 2021: 6 · 2020: 5 · 2019: 3
FWCI
2.18
Type
journal article
Language
en
Open access
closed
Locations
  • Bioanalysis (publishedVersion)
  • PubMed (publishedVersion)
  • St George's Online Research Archive (St George's University of London) (acceptedVersion)
  • UCL Discovery (University College London) (submittedVersion)
Funders
  • UK NIH Research (ACF-2016-18-016)
  • UK Medical Research Council Fellowships (G1002305, M008665)
  • Ministry of Education and Research of Estonia (TLOKT14014I)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
  • Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Clinical Trials
Keywords
detection limit, pharmacokinetic analysis, pharmacokinetic modeling, method validation, imprecise data, regulatory guidelines, pharmacometrics
MeSH terms
Chromatography, Gas, Chromatography, Liquid, Pharmaceutical Preparations, Models, Theoretical, Pharmacokinetics, Reproducibility of Results, Guidelines as Topic, Government Regulation, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review