Evaluation Of Various Doses Of Recombinant Human Thyrotropin In Patients With Multinodular Goiters
Abstract
Objective To assess the safety, adverse effects, and radioactive iodine uptake (RAIU) of recombinant human thyrotropin (rhTSH) using a range of doses in patients with multinodular goiters.Methods In this open-label study conducted between June 2002 and December 2004, euthyroid patients with small nontoxic multinodular goiters and normal thyrotropin concentrations were recruited from 4 sites in the United States. Baseline assessments included thyroid function tests, electrocardiogram, Holter monitoring, hyperthyroid symptom scale, flow-volume loop, and measurement of thyroglobulin and thyroperoxidase antibodies. Patients had a baseline 24-hour scan and thyroid iodine I 123 ((123)I) uptake evaluated at 6, 24, and 48 hours after rhTSH administration. Each patient received a single intramuscular injection of 0.03-mg, 0.1-mg, or 0.3-mg rhTSH followed 24 hours later by 400 microCi (123)I orally. Iodine 123 uptakes were again measured 6, 24, and 48 hours later, and a scintigram scan was performed at 24 hours. Thyroid function tests, flow-volume loop, Holter monitoring and/or electrocardiograms, and thyroid ultrasonography to assess thyroid size were performed serially.Results Twenty-eight patients participated. Median goiter size was 20 mL (range, 7-79 mL). After each rhTSH dose, the radioiodine uptake approximately doubled at each time point compared with baseline uptake. Small rises in serum thyroxine and triiodothyronine were seen in some patients, especially after 0.3-mg rhTSH, and mild symptoms of hyperthyroidism developed in several patients. Flow-volume loop showed transient, mild asymptomatic worsening in 1 patient with a 35.2 mL goiter, although thyroid volume measurements were unchanged. Minor electrocardiogram and/or Holter changes were seen in several patients.Conclusions A flat dose-response curve exists over the range of rhTSH doses tested, with an approximate doubling of thyroid RAIU. All patients tolerated rhTSH well, but the rise in thyroid hormone levels and adverse effects after rhTSH doses of 0.1 mg or higher theoretically might not be well tolerated in older or sicker patients and appear unjustified given the lack of a greater rise in RAIU compared with the 0.03-mg dose. Future studies evaluating rhTSH doses less than 0.1 mg in patients with multinodular goiter are justified.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Worsened chemical hyperthyroidism with increased heart rate and rare supraventricular tachycardia, including atrial fibrillation and atrial flutter, have been observed in patients treated with RAI for TMNG or nontoxic MNG.
“Worsened chemical hyperthyroidism with increased heart rate and rare cases of supraventricular tachycardia, including atrial fibrillation and atrial flutter, have been observed in patients treated with RAI for either TMNG or nontoxic multinodular goiter (MNG) (267-269).”
From 2016 American Thyroid Association Guidelines for Diagnosis and Management of Hyperthyroidism and Other Causes of Thyrotoxicosis (2016) · cites this paper as [268]
In susceptible patients with pre-existing cardiac disease or in the elderly, RAI treatment may produce significant clinical worsening.
“In susceptible patients with pre-existing cardiac disease or in the elderly, RAI treatment may produce significant clinical worsening (268).”
From 2016 American Thyroid Association Guidelines for Diagnosis and Management of Hyperthyroidism and Other Causes of Thyrotoxicosis (2016) · cites this paper as [268]
The citation lists haven’t been fetched yet
References 29 · Cited by 29
- Authors
- Braverman, L., Kloos, R. T., Law, B., Kipnes, M., Dionne, M., & Magner, J.
- Affiliations
- Boston University (US)
- The Ohio State University (US)
- University of Tennessee at Knoxville (US)
- Corresponding author
- Braverman, Lewis
- Venue
- Endocrine Practice
- Publisher
- Elsevier BV
- Published
- 2008-10
- Volume
- 14
- Issue
- 7
- Pages
- 832-839
- ISSN
- 1530-891X (ISSN-L)
- OpenAlex
- W2124584175
- Cited by
- 29
- References
- 29
- Citations by year
- 2024: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 2 · 2017: 3 · 2016: 1 · 2015: 1 · 2014: 3 · 2013: 1 · 2012: 4
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Endocrine Practice (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Cancer Diagnosis and Treatment
- Health Sciences › Medicine › Surgery › Thyroid and Parathyroid Surgery
- Keywords
- recombinant human thyrotropin, multinodular goiter, radioiodine uptake, dose-response relationship, hyperthyroidism, adverse effects, thyroid volume, thyroid peroxidase antibodies, thyroglobulin antibodies
- MeSH terms
- Adolescent, Adult, Aged, Dose-Response Relationship, Drug, Electrocardiography, Female, Goiter, Nodular, Humans, Iodine Radioisotopes, Male, Middle Aged, Recombinant Proteins, Thyroid Function Tests, Thyroid Gland, Thyrotropin
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review