Piezo1: Properties of a cation selective mechanical channel
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Piezo ion channels have been found to be essential for mechanical responses in cells. These channels were first shown to exist in Neuro2A cells, and the gene was identified by siRNAs that diminished the mechanical response. Piezo channels are approximately 2500 amino acids long, have between 24-32 transmembrane regions, and appear to assemble into tetramers and require no other proteins for activity. They have a reversal potential around 0 mV and show voltage dependent inactivation. The channel is constitutively active in liposomes, indicating that no cytoskeletal elements are required. Heterologous expression of the Piezo protein can create mechanical sensitivity in otherwise insensitive cells. Piezo1 currents in outside-out patches were blocked by the extracellular MSC inhibitor peptide GsMTx4. Both enantiomeric forms of GsMTx4 inhibited channel activity in a manner similar to endogenous mechanical channels. Piezo1 can adopt a tonic (non-inactivating) form with repeated stimulation. The transition to the non-inactivating form generally occurs in large groups of channels, indicating that the channels exist in domains, and once the domain is compromised, the members simultaneously adopt new properties. Piezo proteins are associated with physiological responses in cells, such as the reaction to noxious stimulus of Drosophila larvae. Recent work measuring cell crowding, shows that Piezo1 is essential for the removal of extra cells without apoptosis. Piezo1 mutations have also been linked to the pathological response of red blood cells in a genetic disease called Xerocytosis. These finding suggest that Piezo1 is a key player in cells' responses to mechanical stimuli.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezo1 and Piezo2 Are Essential Components of Distinct Mechanically Activated Cation Channels
Coste, B., Mathur, J., Schmidt, M., Earley, T. J., Ranade, S., Petrus, M. J., Dubin, A. E., & Patapoutian, A. (2010) · Science · doi:10.1126/science.1193270 · Cited by 3,316 · cited 14×
“Coste et al.(13) showed that Piezo channels are inhibited by Ruthenium Red, a nonspecific inhibitor of many cation channels, but its lack of specificity limits its usefulness.”
BackgroundMethodInfluentialThe Mechanosensitive Ion Channel Piezo1 Is Inhibited by the Peptide GsMTx4
Bae, C., Sachs, F., & Gottlieb, P. A. (2011) · Biochemistry · doi:10.1021/bi200770q · Cited by 566 · cited 7×
“Patapoutian), we found mechanically stimulated channel activity with voltage-dependent inactivation, a reversal potential near 0 mV and a pressure dependency similar to the cell attached recordings.(29) This activity was suppressed by GsMTx4 with a K d near 200 nM.”
BackgroundInfluentialSelf-citation
Cited by
Mechanosensing is critical for axon growth in the developing brain
Koser, D. E., Thompson, A. J., Foster, S. K., Dwivedy, A., Pillai, E. K., Sheridan, G. K., Svoboda, H., Viana, M., Costa, L. D. F., Guck, J., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4394 · Cited by 649
Architecture of the mammalian mechanosensitive Piezo1 channel
Ge, J., Li, W., Zhao, Q., Li, N., Chen, M., Zhi, P., Li, R., Gao, N., Xiao, B., & Yang, M. (2015) · Nature · doi:10.1038/nature15247 · Cited by 529
Lee, W., Leddy, H. A., Chen, Y., Lee, S. H., Zelenski, N. A., McNulty, A. L., Wu, J., Beicker, K. N., Coles, J., Zauscher, S., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1414298111 · Cited by 460
Self-citationAlbuisson, J., Murthy, S. E., Bandell, M., Coste, B., Louis-dit-Picard, H., Mathur, J., Fénéant-Thibault, M., Tertian, G., de Jaureguiberry, J.-P., Syfuss, P.-Y., et al. (2013) · Nature Communications · doi:10.1038/ncomms2899 · Cited by 377
Multiple clinical forms of dehydrated hereditary stomatocytosis arise from mutations in PIEZO1
Andolfo, I., Alper, S. L., De Franceschi, L., Auriemma, C., Russo, R., De Falco, L., Vallefuoco, F., Esposito, M. R., Vandorpe, D. H., Shmukler, B. E., et al. (2013) · Blood · doi:10.1182/blood-2013-02-482489 · Cited by 321
Metadata
- Authors
- Gottlieb, P. A., & Sachs, F.
- Venue
- Channels
- Publisher
- Informa UK Limited
- Published
- 2012-07
- Volume
- 6
- Issue
- 4
- Pages
- 214-219
- ISSN
- 1933-6950 (ISSN-L)
- 1933-6969
- OpenAlex
- W1976176467
- Cited by
- 138
- References
- 2
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Piezo1: Properties of a cation selective mechanical channel. https://app.cochat.ai/papers/10.4161/chan.21050
- The paper
- Gottlieb, P. A., & Sachs, F. (2012). Piezo1: Properties of a cation selective mechanical channel. Channels. https://doi.org/10.4161/chan.21050
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.