Diagnostic test accuracy: application and practice using R software
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The objective of this paper is to describe general approaches of diagnostic test accuracy (DTA) that are available for the quantitative synthesis of data using R software. We conduct a DTA that summarizes statistics for univariate analysis and bivariate analysis. The package commands of R software were “metaprop” and “metabin” for sensitivity, specificity, and diagnostic odds ratio; forest for forest plot; reitsma of “mada” for a summarized receiver-operating characteristic (ROC) curve; and “metareg” for meta-regression analysis. The estimated total effect sizes, test for heterogeneity and moderator effect, and a summarized ROC curve are reported using R software. In particular, we focus on how to calculate the effect sizes of target studies in DTA. This study focuses on the practical methods of DTA rather than theoretical concepts for researchers whose fields of study were non-statistics related. By performing this study, we hope that many researchers will use R software to determine the DTA more easily, and that there will be greater interest in related research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reitsma, J. B., Glas, A. S., Rutjes, A. W. S., Scholten, R. J. P. M., Bossuyt, P. M., & Zwinderman, A. H. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.02.022 · Cited by 3,369
Research works printed but not linked: 8
- Shim, 2015, Meta-analysis of diagnostic tests accuracy using STATA software, 190
- 10.1002/sim.4780121403 · DOI · Paper page
- 10.1177/0272989X9301300408 · DOI · Paper page
- 10.1002/sim.942 · DOI · Paper page
- 10.1177/0272989X08319957 · DOI · Paper page
- 10.1093/biostatistics/kxl004 · DOI · Paper page
- mada: meta-analysis of diagnostic accuracy
- 10.1001/jamainternmed.2014.1363 · DOI
Cited by
Reintam Blaser, A., Starkopf, J., Björck, M., Forbes, A., Kase, K., Kiisk, E., Laisaar, K.-T., Mihnovits, V., Murruste, M., Mändul, M., et al. (2023) · World Journal of Emergency Surgery · doi:10.1186/s13017-023-00512-9 · Cited by 67
Magalhaes, C., Mendes, J., & Vardasca, R. (2021) · Applied Sciences · doi:10.3390/app11020842 · Cited by 49
Hinojosa-Amaya, J. M., González-Colmenero, F. D., Alvarez-Villalobos, N. A., Salcido-Montenegro, A., Quintanilla-Sánchez, C., Moreno-Peña, P. J., Manzanares-Gallegos, D. M., Gutiérrez-Dávila, L. F., Castillo-Morales, P. L., García-Campa, M., et al. (2024) · Pituitary · doi:10.1007/s11102-024-01408-w · Cited by 14
Metadata
- Authors
- Shim, S. R., Kim, S.-J., & Lee, J.
- Venue
- Epidemiology and Health
- Publisher
- Korean Society of Epidemiology
- Published
- 2019-03-28
- Volume
- 41
- Pages
- e2019007
- ISSN
- 1225-3596 (ISSN-L)
- 2092-7193
- OpenAlex
- W2934145981
- Cited by
- 198
- References
- 1
- FWCI
- 10.68
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diagnostic test accuracy: application and practice using R software. https://app.cochat.ai/papers/10.4178/epih.e2019007
- The paper
- Shim, S. R., Kim, S.-J., & Lee, J. (2019). Diagnostic test accuracy: application and practice using R software. Epidemiology and Health. https://doi.org/10.4178/epih.e2019007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.