OBJECTIVE: To describe survival outcomes with noninvasive ventilation (NIV) for full ventilatory support, and a mechanically assisted cough and oximetry protocol in a series of patients with Duchenne muscular dystrophy. METHODS: We monitored end-tidal carbon dioxide (P(ETCO(2))), S(pO(2)), vital capacity, maximum insufflation capacity, and cough peak flow. Nocturnal NIV was initiated for symptomatic hypoventilation. An oximeter and mechanically assisted cough device were prescribed when the patient's maximum assisted cough peak flow fell below 300 L/min. Patients used up to continuous NIV and mechanically assisted cough to return S(pO(2)) to ≥ 95% during intercurrent respiratory infections or as otherwise needed. We recorded respiratory and cardiac hospitalizations and mortality, and quantified survival by duration of continuous NIV dependence (ie, unable to maintain oxygenation without the ventilator). RESULTS: With advancing Duchenne muscular dystrophy, 101 nocturnal-only NIV users extended their NIV use throughout the daytime hours and required it continuously for 7.4 ± 6.1 years to 30.1 ± 6.1 years of age, with 56 patients still alive. Twenty-six of the 101 became continuously dependent without requiring hospitalization. Eight tracheostomized users were decannulated to NIV. Thirty-one consecutive unweanable intubated patients were extubated to NIV plus mechanically assisted cough. Of the 67 deaths (including 8 patients who died from heart failure before requiring ventilator use), 34 (52%) were probably cardiac, 14 (21%) were probably respiratory, and 19 (27%) were of unknown or other etiology. CONCLUSIONS: Continuous NIV along with mechanically assisted cough and oximetry as needed can prolong life and obviate tracheotomy in patients with Duchenne muscular dystrophy. Unweanable patients can be decannulated and extubated to NIV plus mechanically assisted cough.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4187/respcare.00831

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 241

Metadata

Authors
Bach, J. R., & Martinez, D.
Venue
Respiratory Care
Published
2011-06-01
Volume
56
Issue
6
Pages
744-750
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2104457888
Cited by
241
References
32
FWCI
12.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Duchenne Muscular Dystrophy: Continuous Noninvasive Ventilatory Support Prolongs Survival. https://app.cochat.ai/papers/10.4187/respcare.00831
The paper
Bach, J. R., & Martinez, D. (2011). Duchenne Muscular Dystrophy: Continuous Noninvasive Ventilatory Support Prolongs Survival. Respiratory Care. https://doi.org/10.4187/respcare.00831

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.