The DOI matches its Crossref record.
Facing the Noise: Addressing the Endemic Variability in D LCO Testing
Open accessAbstract
Single-breath diffusing capacity of the lung for carbon monoxide (D(LCO)) is a common pulmonary function test that measures the ability of the lung to exchange gas across the alveolar-capillary interface. D(LCO) testing is used to narrow the differential diagnosis of obstructive and restrictive lung disease, to aid in disability and transplant assessment, and to monitor medication toxicity. The variability in the measurement limits the utility of the test. Variability is attributable to differences in equipment, testing conditions, patient factors, and reference equations. Laboratories can minimize variability by ensuring that equipment meets recommended standards, implementing effective quality control programs, standardizing testing conditions and testing procedures, and accounting for pertinent patient characteristics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The incongruity of increased FVC with stable DLCO may be attributed to low numbers of patients in each treatment arm and the inherent variability of DLCO measurement.
“The incongruity of increased FVC with stable DLCO may be attributed to low numbers of patients in each treatment arm and the inherent variability of DLCO measurement41.”
From A generative AI-discovered TNIK inhibitor for idiopathic pulmonary fibrosis: a randomized phase 2a trial (2025) · cites this paper as [41]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 41
- 10.1164/ajrccm/143.2.219 · DOI
- 10.1378/chest.120.1.88 · DOI
- 10.1016/j.rmed.2006.09.003 · DOI
- 10.1016/0002-9343(86)90620-0 · DOI
- 10.1378/chest.101.4.965 · DOI
- 10.1378/chest.123.5.1394 · DOI
- 10.1056/NEJM198405103101903 · DOI
- 10.1378/chest.93.3.454 · DOI
- 10.1378/chest.85.1.69 · DOI
- 10.1016/j.ejcts.2006.01.014 · DOI
- 10.1164/rccm.200210-1245OC · DOI
- 10.1183/09031936.05.00034905 · DOI
- 10.1378/chest.123.4.1082 · DOI
- 10.1378/chest.126.4_MeetingAbstracts.797S-a · DOI
- 10.1378/chest.06-1998 · DOI
- 10.1378/chest.06-1999 · DOI
- 10.1136/thx.41.2.133 · DOI
- 10.1136/thx.18.2.151 · DOI
- 10.1164/ajrccm/146.4.946 · DOI
- Jensen RL, 2003, Respir Care, 48, 777
- 10.1164/rccm.200801-090OC · DOI
- Enright PE, 2007, Am J Respir Crit Care Med, A606
- 10.1183/09031936.00091208 · DOI
- Pulmonary function laboratory management and procedure manual, 2nd edition. New York: American Thoracic Society; 2005.
- 10.1378/chest.125.2.446 · DOI
- 10.1164/ajrccm.152.1.7599851 · DOI
- 10.1152/jappl.1966.21.2.539 · DOI
- 10.1183/09031936.05.00035205 · DOI · Paper page
- 10.1164/ajrccm.159.1.9712108 · DOI
- Crapo RO, 1981, Am Rev Respir Dis, 123, 185
- 10.1164/arrd.1987.135.4.805 · DOI
- Miller A, 1983, Am Rev Respir Dis, 127, 270
- Paoletti P, 1985, Am Rev Respir Dis, 132, 806
- 10.1164/ajrccm/141.4_Pt_1.1026 · DOI
- 10.1136/thx.2007.091959 · DOI
- 10.1183/09031936.01.00246701 · DOI
- 10.1183/09031936.01.17201680 · DOI
- 10.1053/rmed.1999.0740 · DOI
- Fitting JW, 2004, Swiss Med Wkly, 134, 413
- 10.1164/ajrccm/140.6.1818 · DOI
- 10.1164/ajrccm/146.4.946 · DOI
Cited by
Sorted by citations
Xu, Z., Ren, F., Wang, P., Cao, J., Tan, C., Ma, D., Zhao, L., Dai, J., Ding, Y., Fang, H., et al. (2025) · Nature Medicine · doi:10.1038/s41591-025-03743-2 · Cited by 180
“The incongruity of increased FVC with stable DLCO may be attributed to low numbers of patients in each treatment arm and the inherent variability of DLCO measurement 41 .”
Metadata
- Authors
- McCormack, M. C.
- Affiliations
- Johns Hopkins University (US)
- Corresponding author
- McCormack, Meredith C
- Venue
- Respiratory Care
- Publisher
- SAGE Publications
- Published
- 2012-01-01
- Volume
- 57
- Issue
- 1
- Pages
- 17-25
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2163958514
- Cited by
- 22
- References
- 0
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 4 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 1 · 2015: 1 · 2014: 1 · 2012: 1
- FWCI
- 0.77
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Respiratory Care (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Environmental Health Sciences (K23ES016819)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Interstitial Lung Diseases and Idiopathic Pulmonary Fibrosis
- Keywords
- diffusing capacity for carbon monoxide, measurement noise, pulmonary function tests, quality control, reference equations, equipment standards, patient factors, obstructive lung disease, restrictive lung disease, pre-transplant evaluation, disability assessment
- MeSH terms
- Carbon Dioxide, Humans, Lung Diseases, Lung Diseases, Obstructive, Pulmonary Diffusing Capacity, Quality Control, Reference Values, Reproducibility of Results, Lung Diseases, Interstitial
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review