Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 182

The DOI matches its Crossref record.

Heated and Humidified High-Flow Oxygen Therapy Reduces Discomfort During Hypoxemic Respiratory Failure

Cuquemelle, Elise, Pham, Tai, Papon, Jean-François, Louis, Bruno, Danin, Pierre-Eric, Brochard, Laurent · 2012 · Respiratory Care

Abstract

BACKGROUND: Non-intubated critically ill patients are often treated by high-flow oxygen for acute respiratory failure. There is no current recommendation for humidification of oxygen devices. METHODS: We conducted a prospective randomized trial with a final crossover period to compare nasal airway caliber and respiratory comfort in patients with acute hypoxemic respiratory failure receiving either standard oxygen therapy with no humidification or heated and humidified high-flow oxygen therapy (HHFO₂) in a medical ICU. Nasal airway caliber was measured using acoustic rhinometry at baseline, after 4 and 24 hours (H4 and H24), and 4 hours after crossover (H28). Dryness of the nose, mouth, and throat was auto-evaluated and assessed blindly by an otorhinolaryngologist. After the crossover, the subjects were asked which system they preferred. RESULTS: Thirty subjects completed the protocol and were analyzed. Baseline median oxygen flow was 9 and 12 L/min in the standard and HHFO₂ groups, respectively (P = .21). Acoustic rhinometry measurements showed no difference between the 2 systems. The dryness score was significantly lower in the HHFO₂ group at H4 (2 vs 6, P = .007) and H24 (0 vs 8, P = .004). During the crossover period, dryness increased promptly after switching to standard oxygen and decreased after switching to HHFO₂ (P = .008). Sixteen subjects (53%) preferred HHFO₂ (P = .01), especially those who required the highest flow of oxygen at admission (P = .05). CONCLUSIONS: Upper airway caliber was not significantly modified by HHFO₂, compared to standard oxygen therapy, but HHFO₂ significantly reduced discomfort in critically ill patients with respiratory failure. The system is usually preferred over standard oxygen therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4187/respcare.01681

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 182

Metadata

Authors
Cuquemelle, E., Pham, T., Papon, J.-F., Louis, B., Danin, P.-E., & Brochard, L.
Venue
Respiratory Care
Published
2012-10-01
Volume
57
Issue
10
Pages
1571-1577
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2118541594
Cited by
182
References
0
FWCI
6.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heated and Humidified High-Flow Oxygen Therapy Reduces Discomfort During Hypoxemic Respiratory Failure. https://app.cochat.ai/papers/10.4187/respcare.01681
The paper
Cuquemelle, E., Pham, T., Papon, J.-F., Louis, B., Danin, P.-E., & Brochard, L. (2012). Heated and Humidified High-Flow Oxygen Therapy Reduces Discomfort During Hypoxemic Respiratory Failure. Respiratory Care. https://doi.org/10.4187/respcare.01681

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.