The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
High-Flow Oxygen Administration by Nasal Cannula for Adult and Perinatal Patients
Abstract
The nasal cannula has been a commonly used patient interface to provide supplemental oxygen since its introduction in the 1940s. Traditionally, it has been categorized as a low-flow device and capable of delivering a 0.4 F(IO(2)) with flows up to 6 L/min to adults with normal minute ventilation. However, there is considerable performance variability among patients and design, which results in an exponential decline in delivered F(IO(2)) as breathing frequencies increase. The nasal cannula has also been successfully adapted for use in perinatal and pediatric respiratory care; flows are reduced, in the range of 0.25-1 L/min, due to smaller minute volumes. A decade or so ago, high-flow nasal cannula (HFNC) oxygen therapy was introduced, accompanied by heated humidification systems to prevent the associated drying of upper airway mucosa and to increase patient comfort. Therapeutic flows for adults were in the 15-40 L/min range; F(IO(2)) could be independently adjusted with air/O(2) blending. The HFNC has also found additional clinical application in perinatal care, as delivery systems with flows > 2 L/min could create a distending pressure similar to nasal CPAP. There is a small but growing body of information from clinical trials that supports use of HFNC as an alternative oxygen interface for adults who present with moderate hypoxemia that persists after receiving oxygen by reservoir-bag masks or similar therapy. Clinical observations report greater patient acceptance and comfort versus oxygen masks. HFNC therapy has also been considered valuable in perinatal care in treating the respiratory distress syndrome or supporting patients after extubation similar to nasal CPAP. At present, research-based evidence for the role of HFNC for its perinatal applications remains unclear. This review will identify proposed mechanisms for therapeutic effectiveness, current delivery equipment, guidelines for rational patient application, and direction for further research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preoxygenation and prevention of desaturation during emergency airway management
Weingart, S. D., & Levitan, R. M. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.10.002 · Cited by 554
Cited by
Stéphan, F., Barrucand, B., Petit, P., Rézaiguia-Delclaux, S., Médard, A., Delannoy, B., Cosserant, B., Flicoteaux, G., Imbert, A., Pilorge, C., et al. (2015) · JAMA · doi:10.1001/jama.2015.5213 · Cited by 535
Nasal high flow clears anatomical dead space in upper airway models
Möller, W., Celik, G., Feng, S., Bartenstein, P., Meyer, G., Eickelberg, O., Schmid, O., & Tatkov, S. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00934.2014 · Cited by 320
High-flow nasal oxygen therapy in intensive care and anaesthesia
Renda, T., Corrado, A., Iskandar, G., Pelaia, G., Abdalla, K., & Navalesi, P. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2017.11.010 · Cited by 280
The difficult airway with recommendations for management – Part 2 – The anticipated difficult airway
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0020-x · Cited by 276
Ni, Y.-N., Luo, J., Yu, H., Liu, D., Liang, B.-M., & Liang, Z.-A. (2018) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2017.07.083 · Cited by 112
Metadata
- Authors
- Ward, J. J.
- Venue
- Respiratory Care
- Publisher
- SAGE Publications
- Published
- 2013-01-01
- Volume
- 58
- Issue
- 1
- Pages
- 98-122
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2156882712
- Cited by
- 241
- References
- 1
- FWCI
- 17.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.