The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
AARC Clinical Practice Guideline: Transcutaneous Monitoring of Carbon Dioxide and Oxygen: 2012
Abstract
An electronic literature search for articles published between January 1990 and September 2011 was conducted by using the PubMed, CINAHL, SCOPUS, and Cochrane Library databases. The update of this clinical practice guideline is the result of reviewing a total of 124 articles: 3 randomized controlled trials, 103 prospective trials, 1 retrospective study, 3 case studies, 11 review articles, 2 surveys and 1 consensus paper on transcutaneous monitoring (TCM) for P(tcO(2)) and P(tcCO(2)). The following recommendations are made following the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) criteria: (1) Although P(tcCO(2)) has a good correlation with P(aCO(2)) and is a reliable method to evaluate plasma CO(2) levels, it is recommended that arterial blood gas values be compared to transcutaneous readings taken at the time of arterial sampling, in order to verify the transcutaneous values, and periodically as dictated by the patient's clinical condition. (2) It is suggested that P(tcCO(2)) may be used in clinical settings where monitoring the adequacy of ventilation is indicated. (3) It is suggested that P(tcO(2)) and P(tcCO(2)) may be used in determining the adequacy of tissue perfusion and monitoring of reperfusion. (4) It is suggested that TCM should be avoided in the presence of increased thickness or edema of the skin and/or subcutaneous tissue where the sensor is applied. (5) It is recommended that sites used for a TCM be changed as often as necessary and that they be alternated and observed to avoid thermal injury. Manufacturer recommendations should be followed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GRADE: an emerging consensus on rating quality of evidence and strength of recommendations
Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39489.470347.ad · Cited by 23,305
Use of GRADE grid to reach decisions on clinical practice guidelines when consensus is elusive
Jaeschke, R., Guyatt, G. H., Dellinger, P., Schunemann, H., Levy, M. M., Kunz, R., Norris, S., Bion, J., & for the GRADE working group (2008) · BMJ · doi:10.1136/bmj.a744 · Cited by 577
Cited by
Brat, R., Yousef, N., Klifa, R., Reynaud, S., Shankar Aguilera, S., & De Luca, D. (2015) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2015.1797 · Cited by 472
Guidelines for the physiotherapy management of the adult, medical, spontaneously breathing patient
Bott, J., Blumenthal, S., Buxton, M., Ellum, S., Falconer, C., Garrod, R., Harvey, A., Hughes, T., Lincoln, M., Mikelsons, C., et al. (2009) · Thorax · doi:10.1136/thx.2008.110726 · Cited by 451
De Luca, D., van Kaam, A. H., Tingay, D. G., Courtney, S. E., Danhaive, O., Carnielli, V. P., Zimmermann, L. J., Kneyber, M. C. J., Tissieres, P., Brierley, J., et al. (2017) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(17)30214-x · Cited by 306
Lung Ultrasound Score Predicts Surfactant Need in Extremely Preterm Neonates
De Martino, L., Yousef, N., Ben-Ammar, R., Raimondi, F., Shankar-Aguilera, S., & De Luca, D. (2018) · Pediatrics · doi:10.1542/peds.2018-0463 · Cited by 255
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
Metadata
- Authors
- Restrepo, R. D., Hirst, K. R., Wittnebel, L., & Wettstein, R.
- Venue
- Respiratory Care
- Publisher
- SAGE Publications
- Published
- 2012-11-01
- Volume
- 57
- Issue
- 11
- Pages
- 1955-1962
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2160387133
- Cited by
- 232
- References
- 2
- FWCI
- 15.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AARC Clinical Practice Guideline: Transcutaneous Monitoring of Carbon Dioxide and Oxygen: 2012. https://app.cochat.ai/papers/10.4187/respcare.02011
- The paper
- Restrepo, R. D., Hirst, K. R., Wittnebel, L., & Wettstein, R. (2012). AARC Clinical Practice Guideline: Transcutaneous Monitoring of Carbon Dioxide and Oxygen: 2012. Respiratory Care. https://doi.org/10.4187/respcare.02011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.