The DOI matches its Crossref record.
High-Flow Nasal Cannula Versus Conventional Oxygen Therapy After Endotracheal Extubation: A Randomized Crossover Physiologic Study
Open accessAbstract
OBJECTIVE: Compare the short-term benefit of high-flow nasal cannula (HFNC) with non-rebreathing mask in terms of change in dyspnea, physiologic variables, and patient comfort in subjects after endotracheal extubation. METHODS: A randomized crossover study was conducted in a 10-bed respiratory care unit in a university hospital. Seventeen mechanically ventilated subjects were randomized after extubation to either Protocol A (applied HFNC for 30 min, followed by non-rebreathing mask for another 30 min) or Protocol B (applied non-rebreathing mask for 30 min, followed by HFNC for another 30 min). The level of dyspnea, breathing frequency, heart rate, blood pressure, oxygen saturation, and patient comfort were recorded. The results were expressed as mean ± SD, frequency, or percentage. Categorical variables were compared by chi-square test or Fisher exact test, and continuous variables were compared by dependent or paired t test. Statistical significance was defined as P < .05. RESULTS: Seventeen subjects were divided into 2 groups: 9 subjects in Protocol A and 8 subjects in Protocol B. The baseline characteristics and physiologic parameters before extubation were not significantly different in each protocol. At the end of study, HFNC indicated less dyspnea (P = .04) and lower breathing frequency (P = .009) and heart rate (P = .006) compared with non-rebreathing mask. Most of the subjects (88.2%) preferred HFNC to non-rebreathing mask. CONCLUSIONS: HFNC can improve dyspnea and physiologic parameters, including breathing frequency and heart rate, in extubated subjects compared with conventional oxygen therapy. This device may have a potential role for use after endotracheal extubation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Failure of high-flow nasal cannula therapy may delay intubation and increase mortality
Kang, B. J., Koh, Y., Lim, C.-M., Huh, J. W., Baek, S., Han, M., Seo, H.-S., Suh, H. J., Seo, G. J., Kim, E. Y., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3693-5 · Cited by 657
Maggiore, S. M., Idone, F. A., Vaschetto, R., Festa, R., Cataldo, A., Antonicelli, F., Montini, L., De Gaetano, A., Navalesi, P., & Antonelli, M. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201402-0364oc · Cited by 546
Heated Humidified High-Flow Nasal Oxygen in Adults
Spoletini, G., Alotaibi, M., Blasi, F., & Hill, N. S. (2015) · Chest · doi:10.1378/chest.14-2871 · Cited by 406
Rochwerg, B., Einav, S., Chaudhuri, D., Mancebo, J., Mauri, T., Helviz, Y., Goligher, E. C., Jaber, S., Ricard, J.-D., Rittayamai, N., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06312-y · Cited by 394
Self-citationERS clinical practice guidelines: high-flow nasal cannula in acute respiratory failure
Oczkowski, S., Ergan, B., Bos, L., Chatwin, M., Ferrer, M., Gregoretti, C., Heunks, L., Frat, J.-P., Longhini, F., Nava, S., et al. (2022) · European Respiratory Journal · doi:10.1183/13993003.01574-2021 · Cited by 388
Metadata
- Authors
- Rittayamai, N., Tscheikuna, J., & Rujiwit, P.
- Venue
- Respiratory Care
- Publisher
- SAGE Publications
- Published
- 2014-04-01
- Volume
- 59
- Issue
- 4
- Pages
- 485-490
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2148650897
- Cited by
- 165
- References
- 0
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Flow Nasal Cannula Versus Conventional Oxygen Therapy After Endotracheal Extubation: A Randomized Crossover Physiologic Study. https://app.cochat.ai/papers/10.4187/respcare.02397
- The paper
- Rittayamai, N., Tscheikuna, J., & Rujiwit, P. (2014). High-Flow Nasal Cannula Versus Conventional Oxygen Therapy After Endotracheal Extubation: A Randomized Crossover Physiologic Study. Respiratory Care. https://doi.org/10.4187/respcare.02397
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.