Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 204

The DOI matches its Crossref record.

Sequential Application of Oxygen Therapy Via High-Flow Nasal Cannula and Noninvasive Ventilation in Acute Respiratory Failure: An Observational Pilot Study

Open access
Frat, Jean-Pierre, Brugiere, Benjamin, Ragot, Stéphanie, Chatellier, Delphine, Veinstein, Anne, Goudet, Véronique, Coudroy, Rémi, Petitpas, Franck, Robert, René, Thille, Arnaud W, Girault, Christophe · 2015 · Respiratory Care

Abstract

BACKGROUND: The aim of this study was to evaluate the clinical efficacy of humidified oxygen via high-flow nasal cannula (HFNC) alternating with noninvasive ventilation (NIV) in acute hypoxemic respiratory failure (AHRF). METHODS: We performed a prospective observational study in a 12-bed ICU of a university hospital. All subjects with a PaO2 /FIO2 of ≤300 mm Hg with standard mask oxygen and a breathing frequency of > 30 breaths/min or signs of respiratory distress were included and treated with HFNC first and then NIV. Ventilatory parameters, blood gases, and tolerance were recorded during 2 consecutive sessions of NIV and HFNC. Outcome was assessed after continuation of this noninvasive strategy. RESULTS: Twenty-eight subjects with AHRF were studied, including 23 (82%) with ARDS. Compared with standard oxygen therapy, PaO2 significantly increased from 83 (68-97) mm Hg to 108 (83-140) mm Hg using HFNC and to 125 (97-200) mm Hg using NIV (P<.01), whereas breathing frequency significantly decreased. HFNC was significantly better tolerated than NIV, with a lower score on the visual analog scale. The non-intubated subjects received HFNC for 75 (27-127) h and NIV for 23 (8-31) h. Intubation was required in 10 of 28 subjects (36%), including 8 of 23 subjects with ARDS (35%). After HFNC initiation, a breathing frequency of ≥30 breaths/min was an early factor associated with intubation. CONCLUSIONS: HFNC was better tolerated than NIV and allowed for significant improvement in oxygenation and tachypnea compared with standard oxygen therapy in subjects with AHRF, a large majority of whom had ARDS. Thus, HFNC may be used between NIV sessions to avoid marked impairment of oxygenation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4187/respcare.03075

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 204

Metadata

Authors
Frat, J.-P., Brugiere, B., Ragot, S., Chatellier, D., Veinstein, A., Goudet, V., Coudroy, R., Petitpas, F., Robert, R., Thille, A. W., & Girault, C.
Venue
Respiratory Care
Published
2015-02-01
Volume
60
Issue
2
Pages
170-178
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2103016141
Cited by
204
References
0
FWCI
11.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sequential Application of Oxygen Therapy Via High-Flow Nasal Cannula and Noninvasive Ventilation in Acute Respiratory Failure: An Observational Pilot Study. https://app.cochat.ai/papers/10.4187/respcare.03075
The paper
Frat, J.-P., Brugiere, B., Ragot, S., Chatellier, D., Veinstein, A., Goudet, V., Coudroy, R., Petitpas, F., Robert, R., Thille, A. W., & Girault, C. (2015). Sequential Application of Oxygen Therapy Via High-Flow Nasal Cannula and Noninvasive Ventilation in Acute Respiratory Failure: An Observational Pilot Study. Respiratory Care. https://doi.org/10.4187/respcare.03075

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.