CoChat

Estimation of Minimal Clinically Important Difference in EQ-5D Visual Analog Scale Score After Pulmonary Rehabilitation in Subjects With COPD

Zanini, Andrea, Aiello, Marina, Adamo, Daniela, Casale, Silvia, Cherubino, Francesca, Della Patrona, Sabrina, Raimondi, Eleonora, Zampogna, Elisabetta, Chetta, Alfredo, Spanevello, Antonio · 2015 · Respiratory Care
Cited by 145

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The effect of pulmonary rehabilitation (PR) on the EuroQol Group's 5-dimension questionnaire (EQ-5D) in COPD has been poorly investigated. In addition, conflicting results were reported about the visual analog scale component of EQ-5D (EQ-VAS). The purpose of this study was to evaluate the responsiveness of EQ-VAS to PR and its relationship with clinical and functional parameters in subjects with COPD, as well as to define the minimal clinically important difference (MCID) estimate for the EQ-VAS after PR. METHODS: A total of 468 in-patients with stable moderate-to-severe COPD, allocated to a 3-wk PR program, were retrospectively evaluated. EQ-VAS was assessed before and after PR, and its relationship with baseline pulmonary function, changes in 6-min walk test, and baseline, and transitional dyspnea index (BDI/TDI) after PR were evaluated. Using an anchor-based approach and receiver operating characteristic curves, the EQ-VAS change cutoff that identified subjects achieving the known MCID for TDI after PR was identified. RESULTS: Four hundred and thirty-nine subjects (94%, mean FEV1 55.3% predicted) completed pre- and post-PR EQ-VAS scores. After PR, EQ-VAS increased from 58 ± 17 to 72 ± 15 (ΔEQ-VAS 14 ± 12, P < .001). ΔEQ-VAS was negatively related to baseline FEV1 (r = -0.32, P < .001) and positively to TDI (r = 0.50, P < .001) and 6-min walk distance (r = 0.46, P < .001) changes. Receiver operating characteristic curves identified an EQ-VAS change cutoff of 8 as the best discriminating value to identify the MCID for TDI (0.78 sensitivity and 0.81 specificity; area under curve: 0.845, P < .001). CONCLUSIONS: Our study shows that, in in-patients with stable moderate-to-severe COPD, EQ-VAS is a valid and reliable tool to assess the responsiveness to PR, with an estimated MCID of 8 points. The EQ-VAS can be a practical alternative to more time-consuming measures of health-related quality of life.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4187/respcare.03272

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 145

Metadata

Authors
Zanini, A., Aiello, M., Adamo, D., Casale, S., Cherubino, F., Della Patrona, S., Raimondi, E., Zampogna, E., Chetta, A., & Spanevello, A.
Venue
Respiratory Care
Published
2015-01-01
Volume
60
Issue
1
Pages
88-95
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2163744159
Cited by
145
References
3
FWCI
3.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Estimation of Minimal Clinically Important Difference in EQ-5D Visual Analog Scale Score After Pulmonary Rehabilitation in Subjects With COPD. https://app.cochat.ai/papers/10.4187/respcare.03272
The paper
Zanini, A., Aiello, M., Adamo, D., Casale, S., Cherubino, F., Della Patrona, S., Raimondi, E., Zampogna, E., Chetta, A., & Spanevello, A. (2015). Estimation of Minimal Clinically Important Difference in EQ-5D Visual Analog Scale Score After Pulmonary Rehabilitation in Subjects With COPD. Respiratory Care. https://doi.org/10.4187/respcare.03272

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.