The DOI matches its Crossref record.
Physiologic Effects of High-Flow Nasal Cannula Oxygen in Critical Care Subjects
Open accessAbstract
INTRODUCTION: High-flow nasal cannula (HFNC) can deliver heated and humidified gas (up to 100% oxygen) at a maximum flow of 60 L/min via nasal prongs or cannula. The aim of this study was to assess the short-term physiologic effects of HFNC. Inspiratory muscle effort, gas exchange, dyspnea score, and comfort were evaluated. METHODS: Twelve subjects admitted to the ICU for acute hypoxemic respiratory failure were prospectively included. Four study sessions were performed. The first session consisted of oxygen therapy given through a high-FIO2, non-rebreathing face mask. Recordings were then obtained during periods of HFNC and CPAP at 5 cm H2O in random order, and final measurements were performed during oxygen therapy delivered via a face mask. Each of these 4 periods lasted ∼20 min. RESULTS: Esophageal pressure signals, breathing pattern, gas exchange, comfort, and dyspnea were measured. Compared with the first session, HFNC reduced inspiratory effort (pressure-time product of 156.0 [119.2-194.4] cm H2O × s/min vs 204.2 [149.6-324.7] cm H2O × s/min, P < .01) and breathing frequency (P < .01). No significant differences were observed between HFNC and CPAP for inspiratory effort and breathing frequency. Compared with the first session, PaO2/FIO2 increased significantly with HFNC (167 [157-184] mm Hg vs 156 [110-171] mm Hg, P < .01). CPAP produced significantly greater PaO2/FIO2 improvement than did HFNC. Dyspnea improved with HFNC and CPAP, but this improvement was not significant. Subject comfort was not different across the 4 sessions. CONCLUSIONS: Compared with conventional oxygen therapy, HFNC improved inspiratory effort and oxygenation. In subjects with acute hypoxemic respiratory failure, HFNC is an alternative to conventional oxygen therapy. (ClinicalTrials.gov registration NCT01056952.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory Failure
Mauri, T., Turrini, C., Eronia, N., Grasselli, G., Volta, C. A., Bellani, G., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-0916oc · Cited by 641
Use of high-flow nasal cannula oxygenation in ICU adults: a narrative review
Papazian, L., Corley, A., Hess, D., Fraser, J. F., Frat, J.-P., Guitton, C., Jaber, S., Maggiore, S. M., Nava, S., Rello, J., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4277-8 · Cited by 304
Mauri, T., Alban, L., Turrini, C., Cambiaghi, B., Carlesso, E., Taccone, P., Bottino, N., Lissoni, A., Spadaro, S., Volta, C. A., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4890-1 · Cited by 294
Grieco, D. L., Maggiore, S. M., Roca, O., Spinelli, E., Patel, B. K., Thille, A. W., Barbas, C. S. V., de Acilu, M. G., Cutuli, S. L., Bongiovanni, F., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06459-2 · Cited by 286
Nasal high flow reduces dead space
Möller, W., Feng, S., Domanski, U., Franke, K.-J., Celik, G., Bartenstein, P., Becker, S., Meyer, G., Schmid, O., Eickelberg, O., et al. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00584.2016 · Cited by 266
Metadata
- Authors
- Vargas, F., Saint-Leger, M., Boyer, A., Bui, N. H., & Hilbert, G.
- Venue
- Respiratory Care
- Publisher
- SAGE Publications
- Published
- 2015-10-01
- Volume
- 60
- Issue
- 10
- Pages
- 1369-1376
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2180910451
- Cited by
- 199
- References
- 0
- FWCI
- 10.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physiologic Effects of High-Flow Nasal Cannula Oxygen in Critical Care Subjects. https://app.cochat.ai/papers/10.4187/respcare.03814
- The paper
- Vargas, F., Saint-Leger, M., Boyer, A., Bui, N. H., & Hilbert, G. (2015). Physiologic Effects of High-Flow Nasal Cannula Oxygen in Critical Care Subjects. Respiratory Care. https://doi.org/10.4187/respcare.03814
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.