Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 158

The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.

Measurement of Air Trapping, Intrinsic Positive End-Expiratory Pressure, and Dynamic Hyperinflation in Mechanically Ventilated Patients

Lluís Blanch, Francesca Bernabè, Umberto Lucangelo · 2005 · Respiratory Care

Abstract

Severe airflow obstruction is a common cause of acute respiratory failure. Dynamic hyperinflation affects tidal ventilation, increases airways resistance, and causes intrinsic positive end-expiratory pressure (auto-PEEP). Most patients with asthma and chronic obstructive pulmonary disease have dynamic hyperinflation and auto-PEEP during mechanical ventilation, which can cause hemodynamic compromise and barotrauma. Auto-PEEP can be identified in passively breathing patients by observation of real-time ventilator flow and pressure graphics. In spontaneously breathing patients, auto-PEEP is measured by simultaneous recordings of esophageal and flow waveforms. The ventilatory pattern should be directed toward minimizing dynamic hyperinflation and auto-PEEP by using small tidal volume and preserving expiratory time. With a spontaneously breathing patient, to reduce the work of breathing and improve patient-ventilator interaction, it is crucial to set an adequate inspiratory flow, inspiratory time, trigger sensitivity, and ventilator-applied PEEP. Ventilator graphics are invaluable for monitoring and treatment decisions at the bedside.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.4187/respcare.05500110

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 158

Metadata

Authors
Blanch, L., Bernabè, F., & Lucangelo, U.
Venue
Respiratory Care
Publisher
American Association for Respiratory Care
Published
2005-01-01
Volume
50
Issue
1
Pages
110-124
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2159440351
Cited by
158
References
1
FWCI
6.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.