The DOI matches its OpenAlex record; 4 of the 4 references it cites were found in a registry or an index.
Late Complications of Tracheostomy
Abstract
Complications of tracheotomy are largely preventable. Although some authors cite these complications as indications for prolonged endotracheal intubation to avoid tracheotomy, others believe that the laryngotracheal complications of prolonged endotracheal intubation warrant early tracheotomy. Obviously, unnecessary tracheotomies should not be performed, and the controversy regarding the timing of conversion of endotracheal intubation to tracheotomy is handled in an earlier article in this issue. We feel, however, that a properly performed tracheotomy has a low incidence of complications that are more easily managed than are the complex laryngotracheal complications of prolonged endotracheal intubation. Significant post-tracheotomy tracheal stenosis occurs in 8% of patients and is secondary to an overly large tracheotomy stoma or damage at the tracheostomy tube cuff site. Stoma stenosis can be minimized by not making an overly large tracheal stoma and by prevention of undue leverage on the tracheostomy tube. Cuff stenosis can be minimized by the use of the high-volume low-pressure cuffs with careful prevention of overdistention of the cuff. Bronchoscopic dilatation, laser resection, and Silastic T-tube placement provide control of the airway until definitive surgical resection and reconstruction can be performed safely. Tracheoesophageal fistula is an uncommon but life-threatening complication that can be prevented by avoiding overdistention of the tracheostomy tube cuff and by avoiding the concomitant use of a stiff nasogastric tube. These patients are best managed conservatively until they are able to be weaned from a ventilator. A single-stage repair of both the esophagus and the trachea should then be done. Tracheoinnominate artery fistula can be avoided by correct placement of the tracheostomy stoma through the second and third tracheal rings rather than lower in the trachea and by avoidance of overinflation of tracheostomy tube cuffs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Complications and consequences of endotracheal intubation and tracheotomy
Stauffer, J. L., Olson, D. E., & Petty, T. L. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90413-7 · Cited by 1,211
Tracheostomy in the Intensive Care Unit
Heffner, J. E., Miller, K. S., & Sahn, S. A. (1986) · Chest · doi:10.1378/chest.90.2.269 · Cited by 207
Tracheostomy‐related subglottic stenosis: Bacteriologic pathogenesis
Sasaki, C. T., Horiuchi, M., & Koss, N. (1979) · The Laryngoscope · doi:10.1288/00005537-197906000-00001 · Cited by 189
Tracheostomy in the Intensive Care Unit
Heffner, J. E., Miller, K. S., & Sahn, S. A. (1986) · Chest · doi:10.1378/chest.90.3.430 · Cited by 170
Cited by
Tracheostomy in Infants and Children
Watters, K. F. (2017) · Respiratory Care · doi:10.4187/respcare.05366 · Cited by 310
Long-term outcomes from critical care
Morgan, A. (2021) · Surgery (Oxford) · doi:10.1016/j.mpsur.2020.11.005 · Cited by 70
Metadata
- Authors
- Epstein, S. K.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2005-04-01
- Volume
- 50
- Issue
- 4
- Pages
- 542-549
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W1961557041
- Cited by
- 445
- References
- 4
- FWCI
- 8.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Late Complications of Tracheostomy. https://app.cochat.ai/papers/10.4187/respcare.05500542
- The paper
- Epstein, S. K. (2005). Late Complications of Tracheostomy. Respiratory Care. https://doi.org/10.4187/respcare.05500542
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.