The DOI matches its OpenAlex record.
Delivered Oxygen Concentrations Using Low-Flow and High-Flow Nasal Cannulas
Abstract
INTRODUCTION: Nasal cannulas are commonly used to deliver oxygen in acute and chronic care settings; however, there are few data available on delivered fraction of inspired oxygen (F(IO(2))). The purposes of this study were to determine the delivered F(IO(2)) on human subjects using low-flow and high-flow nasal cannulas, and to determine the effects of mouth-closed and mouth-open breathing on F(IO(2)). METHODS: We measured the pharyngeal F(IO(2)) delivered by adult nasal cannulas at 1-6 L/min and high-flow nasal cannulas at 6-15 L/min consecutively in 10 normal subjects. Oxygen was initiated at 1 L/min, with the subject at rest, followed by a period of rapid breathing. Gas samples were aspirated from a nasal catheter positioned with the tip behind the uvula. This process was repeated at each liter flow. Mean, standard deviation, and range were calculated at each liter flow. F(IO(2)) during mouth-open and mouth-closed breathing were compared using the dependent test for paired values, to determine if there were significant differences. RESULTS: The mean resting F(IO(2)) ranged from 0.26-0.54 at 1-6 L/min to 0.54-0.75 at 6-15 L/min. During rapid breathing the mean F(IO(2)) ranged from 0.24-0.45 at 1-6 L/min to 0.49-0.72 at 6-15 L/min. The mean F(IO(2)) increased with increasing flow rates. The standard deviation (+/- 0.04-0.15) and range were large, and F(IO(2)) varied widely within and between subjects. F(IO(2)) during mouth-open breathing was significantly (p < 0.05) greater than that during mouth-closed breathing. CONCLUSIONS: F(IO(2)) increased with increasing flow. Subjects who breathed with their mouths open attained a significantly higher F(IO(2)), compared to those who breathed with their mouths closed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
BTS guideline for emergency oxygen use in adult patients
O'Driscoll, B. R., Howard, L. S., Davison, A. G., & on behalf of the British Thoracic Society (2008) · Thorax · doi:10.1136/thx.2008.102947 · Cited by 729
BTS guideline for oxygen use in adults in healthcare and emergency settings
O'Driscoll, B. R., Howard, L. S., Earis, J., & Mak, V (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209729 · Cited by 679
Preoxygenation and prevention of desaturation during emergency airway management
Weingart, S. D., & Levitan, R. M. (2012) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.10.002 · Cited by 554
Maggiore, S. M., Idone, F. A., Vaschetto, R., Festa, R., Cataldo, A., Antonicelli, F., Montini, L., De Gaetano, A., Navalesi, P., & Antonelli, M. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201402-0364oc · Cited by 546
High-flow Oxygen Therapy in Acute Respiratory Failure
Masclans, J. R., & Roca, O. (2012) · Clinical Pulmonary Medicine · doi:10.1097/cpm.0b013e3182514f29 · Cited by 489
Metadata
- Authors
- Wettstein, R. B., Shelledy, D. C., & Peters, J. I.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2005-05-01
- Volume
- 50
- Issue
- 5
- Pages
- 604-609
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2121240998
- Cited by
- 220
- References
- 0
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Delivered Oxygen Concentrations Using Low-Flow and High-Flow Nasal Cannulas. https://app.cochat.ai/papers/10.4187/respcare.05500604
- The paper
- Wettstein, R. B., Shelledy, D. C., & Peters, J. I. (2005). Delivered Oxygen Concentrations Using Low-Flow and High-Flow Nasal Cannulas. Respiratory Care. https://doi.org/10.4187/respcare.05500604
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.