Noninvasive Ventilation in Neuromuscular Disease: Equipment and Application
The DOI matches its OpenAlex record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Noninvasive support of ventilation is commonly needed in patients with neuromuscular disease. Body ventilators, which are used rarely, function by applying intermittent negative pressure to the thorax or abdomen. More commonly, noninvasive positive-pressure ventilation (NPPV) is used. This therapy can be applied with a variety of interfaces, ventilators, and ventilator settings. The patient interface has a major impact on comfort during NPPV. The most commonly used interfaces are nasal masks and oronasal masks. Other interfaces include nasal pillows, total face masks, helmets, and mouthpieces. Theoretically, any ventilator can be attached to a mask rather than an artificial airway. Portable pressure ventilators (bi-level positive airway pressure) are available specifically to provide NPPV and are commonly used to provide this therapy. Selection of NPPV settings in patients with neuromuscular disease is often done empirically and is symptom-based. Selection of settings can also be based on the results of physiologic studies or sleep studies. The use of NPPV in this patient population is likely to expand, particularly with increasing evidence that it is life-prolonging in patients with diseases such as amyotrophic lateral sclerosis. Appropriate selection of equipment and settings for NPPV is paramount to the success of this therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Massie, C. A., Hart, R. W., Peralez, K., & Richards, G. N. (1999) · Chest · doi:10.1378/chest.116.2.403 · Cited by 308
Mador, M. J., Krauza, M., Pervez, A., Pierce, D., & Braun, M. (2005) · Chest · doi:10.1378/chest.128.4.2151 · Cited by 150 · cited 1×
“Mador et al 68 reported that addition of heated humidification was associated with fewer symptoms attributable to the upper airway.”
Background
Cited by
Respiratory Dysfunction and Management in Spinal Cord Injury
Brown, R. H., DiMarco, A. F., Hoit, J. D., & Garshick, E. (2006) · Respiratory Care · doi:10.4187/respcare.06510853 · Cited by 429
The growing role of noninvasive ventilation in patients requiring prolonged mechanical ventilation
Hess, D. R. (2012) · Respiratory Care · doi:10.4187/respcare.01692 · Cited by 59
Self-citationPierucci, P., Crimi, C., Carlucci, A., Carpagnano, G. E., Janssens, J.-P., Lujan, M., Noto, A., Wijkstra, P. J., Windisch, W., & Scala, R. (2021) · ERJ Open Research · doi:10.1183/23120541.00911-2020 · Cited by 34
Banfi, P., Pierucci, P., Volpato, E., Nicolini, A., Lax, A., Robert, D., & Bach, J. (2019) · Multidisciplinary Respiratory Medicine · doi:10.1186/s40248-019-0202-7 · Cited by 20
Intermittent Abdominal Pressure Ventilation: An Alternative for Respiratory Support
Fiorentino, G., Annunziata, A., Coppola, A., Marotta, A., Simioli, F., Imitazione, P., Lanza, M., Cauteruccio, R., & Esquinas, A. M. (2021) · Canadian Respiratory Journal · doi:10.1155/2021/5554765 · Cited by 7
Metadata
- Authors
- HESS, D. R.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2006-08-01
- Volume
- 51
- Issue
- 8
- Pages
- 896-912
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2299285819
- Cited by
- 79
- References
- 2
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Ventilation in Neuromuscular Disease: Equipment and Application. https://app.cochat.ai/papers/10.4187/respcare.06510896
- The paper
- HESS, D. R. (2006). Noninvasive Ventilation in Neuromuscular Disease: Equipment and Application. Respiratory Care. https://doi.org/10.4187/respcare.06510896
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.