Comparison of Measured Versus Predicted Energy Requirements in Critically Ill Cancer Patients
The DOI matches its OpenAlex record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Accurate determination of caloric requirements is essential to avoid feeding-associated complications in critically ill patients. METHODS: In critically ill cancer patients we compared the measured and estimated resting energy expenditures. All patients admitted to the oncology intensive care unit between March 2004 and July 2005 were considered for inclusion. For those patients enrolled (n = 34) we measured resting energy expenditure via indirect calorimetry, and estimated resting energy expenditure in 2 ways: clinically estimated resting energy expenditure; and the Harris-Benedict basal energy expenditure equation. RESULTS: Clinically estimated resting energy expenditure was associated with underfeeding, appropriate feeding, and overfeeding in approximately 15%, 15%, and 71% of the patients, respectively. The Harris-Benedict basal energy expenditure was associated with underfeeding, appropriate feeding, and overfeeding in approximately 29%, 41%, and 29% of the patients, respectively. The mean measured resting energy expenditure (1,623 +/- 384 kcal/d) was similar to the mean Harris-Benedict basal energy expenditure without the addition of stress or activity factors (1,613 +/- 382 kcal/d, P = .87), and both were significantly lower than the mean clinically estimated resting energy expenditure (1,862 +/- 330 kcal/d, P < or = .003 for both). There was a significant correlation only between mean measured resting energy expenditure and mean Harris-Benedict basal energy expenditure (P < .001), but the correlation coefficient between those values was low (r = 0.587). CONCLUSIONS: Underfeeding and overfeeding were common in our critically ill cancer patients when resting energy expenditure was estimated rather than measured. Indirect calorimetry is the method of choice for determining caloric need in critically ill cancer patients, but if indirect calorimetry is not available or feasible, the Harris-Benedict equation without added stress and activity factors is more accurate than the clinically estimated resting energy expenditure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Negative impact of hypocaloric feeding and energy balance on clinical outcome in ICU patients
Villet, S., Chiolero, R. L., Bollmann, M. D., Revelly, J.-P., Cayeux RN, M.-C., Delarue, J., & Berger, M. M. (2005) · Clinical Nutrition · doi:10.1016/j.clnu.2005.03.006 · Cited by 995
Cited by
ESPEN guidelines on nutrition in cancer patients
Arends, J., Bachmann, P., Baracos, V., Barthelemy, N., Bertz, H., Bozzetti, F., Fearon, K., Hütterer, E., Isenring, E., Kaasa, S., et al. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2016.07.015 · Cited by 3,114
Tatucu‐Babet, O. A., Ridley, E. J., & Tierney, A. C. (2016) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607114567898 · Cited by 133
“To account for these increases and to prevent underfeeding, predictive equations are generally multiplied by an SF.(17,31) Although a topic of interest in early studies,(35) the selection of SFs represents an area that is lacking in robust research.”
BackgroundMethodResultInfluentialWhich Nutritional Regimen for the Comorbid Complex Intensive Care Unit Patient?
Singer, P., Weinberger, H., & Tadmor, B. (2013) · World Review of Nutrition and Dietetics · doi:10.1159/000341294 · Cited by 9
Metadata
- Authors
- Pirat, A., Tucker, A. M., Taylor, K. A., Jinnah, R., Finch, C., Canada, T. D., & Nates, J. L.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2009-04-01
- Volume
- 54
- Issue
- 4
- Pages
- 487-494
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2147872788
- Cited by
- 45
- References
- 1
- FWCI
- 3.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.