Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 302

The DOI matches its OpenAlex record; 17 of the 17 references it cites were found in a registry or an index.

High-Flow Oxygen Therapy in Acute Respiratory Failure

Oriol Roca, Jordi Riera, Ferràn Torres, Joan Ramón Masclans·2010·Respiratory Care

Abstract

OBJECTIVE: To compare the comfort of oxygen therapy via high-flow nasal cannula (HFNC) versus via conventional face mask in patients with acute respiratory failure. Acute respiratory failure was defined as blood oxygen saturation < 96% while receiving a fraction of inspired oxygen > or = 0.50 via face mask. METHODS: Oxygen was first humidified with a bubble humidifier and delivered via face mask for 30 min, and then via HFNC with heated humidifier for another 30 min. At the end of each 30-min period we asked the patient to evaluate dyspnea, mouth dryness, and overall comfort, on a visual analog scale of 0 (lowest) to 10 (highest). The results are expressed as median and interquartile range values. RESULTS: We included 20 patients, with a median age of 57 (40-70) years. The total gas flow administered was higher with the HFNC than with the face mask (30 [21.3-38.7] L/min vs 15 [12-20] L/min, P < .001). The HFNC was associated with less dyspnea (3.8 [1.3-5.8] vs 6.8 [4.1-7.9], P = .001) and mouth dryness (5 [2.3-7] vs 9.5 [8-10], P < .001), and was more comfortable (9 [8-10]) versus 5 [2.3-6.8], P < .001). HFNC was associated with higher P(aO(2)) (127 [83-191] mm Hg vs 77 [64-88] mm Hg, P = .002) and lower respiratory rate (21 [18-27] breaths/min vs 28 [25-32] breaths/min, P < .001), but no difference in P(aCO(2)). CONCLUSIONS: HFNC was better tolerated and more comfortable than face mask. HFNC was associated with better oxygenation and lower respiratory rate. HFNC could have an important role in the treatment of patients with acute respiratory failure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

OpenAlex · 10.4187/respcare.10550408

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 302

Metadata

Authors
Roca, O., Riera, J., Torres, F., & Masclans, J. R.
Venue
Respiratory Care
Publisher
American Association for Respiratory Care
Published
2010-04-01
Volume
55
Issue
4
Pages
408-413
ISSN
0020-1324 (ISSN-L)
OpenAlex
W2183974602
Cited by
302
References
17
FWCI
4.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Flow Oxygen Therapy in Acute Respiratory Failure. https://app.cochat.ai/papers/10.4187/respcare.10550408
The paper
Roca, O., Riera, J., Torres, F., & Masclans, J. R. (2010). High-Flow Oxygen Therapy in Acute Respiratory Failure. Respiratory Care. https://doi.org/10.4187/respcare.10550408

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.