The DOI matches its OpenAlex record; 17 of the 17 references it cites were found in a registry or an index.
High-Flow Oxygen Therapy in Acute Respiratory Failure
Abstract
OBJECTIVE: To compare the comfort of oxygen therapy via high-flow nasal cannula (HFNC) versus via conventional face mask in patients with acute respiratory failure. Acute respiratory failure was defined as blood oxygen saturation < 96% while receiving a fraction of inspired oxygen > or = 0.50 via face mask. METHODS: Oxygen was first humidified with a bubble humidifier and delivered via face mask for 30 min, and then via HFNC with heated humidifier for another 30 min. At the end of each 30-min period we asked the patient to evaluate dyspnea, mouth dryness, and overall comfort, on a visual analog scale of 0 (lowest) to 10 (highest). The results are expressed as median and interquartile range values. RESULTS: We included 20 patients, with a median age of 57 (40-70) years. The total gas flow administered was higher with the HFNC than with the face mask (30 [21.3-38.7] L/min vs 15 [12-20] L/min, P < .001). The HFNC was associated with less dyspnea (3.8 [1.3-5.8] vs 6.8 [4.1-7.9], P = .001) and mouth dryness (5 [2.3-7] vs 9.5 [8-10], P < .001), and was more comfortable (9 [8-10]) versus 5 [2.3-6.8], P < .001). HFNC was associated with higher P(aO(2)) (127 [83-191] mm Hg vs 77 [64-88] mm Hg, P = .002) and lower respiratory rate (21 [18-27] breaths/min vs 28 [25-32] breaths/min, P < .001), but no difference in P(aCO(2)). CONCLUSIONS: HFNC was better tolerated and more comfortable than face mask. HFNC was associated with better oxygenation and lower respiratory rate. HFNC could have an important role in the treatment of patients with acute respiratory failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664
APACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376
Vincent, J. L., Moreno, R., Takala, J., Willatts, S., De Mendonça, A., Bruining, H., Reinhart, C. K., Suter, P. M., & Thijs, L. G. (1996) · Intensive Care Medicine · doi:10.1007/bf01709751 · Cited by 11,674
APACHE II: a severity of disease classification system.
Knaus, W. A., Draper, E. S., Wagner, D. P., & Zimmerman, J. E. (1985) · PubMed · Cited by 6,034
An Expanded Definition of the Adult Respiratory Distress Syndrome
Murray, J. F., Matthay, M. A., Luce, J. M., & Flick, M. R. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.3.720 · Cited by 2,646
Aitken, R. C. B. (1969) · Proceedings of the Royal Society of Medicine · doi:10.1177/003591576906201005 · Cited by 1,539
Wilson, R. C., & Jones, P. W. (1989) · Clinical Science · doi:10.1042/cs0760277 · Cited by 505
Sample Size Determination for Some Common Nonparametric Tests
Noether, G. E. (1987) · Journal of the American Statistical Association · doi:10.1080/01621459.1987.10478478 · Cited by 307
Measurement of breathlessness in advanced disease: A systematic review
Bausewein, C., Farquhar, M., Booth, S., Gysels, M., & Higginson, I. J. (2007) · Respiratory Medicine · doi:10.1016/j.rmed.2006.07.003 · Cited by 274
Validation of a Vertical Visual Analogue Scale as a Measure of Clinical Dyspnea
Gift, A. G. (1989) · Rehabilitation Nursing · doi:10.1002/j.2048-7940.1989.tb01129.x · Cited by 258
Cited by
Patel, A., & Nouraei, S. A. R. (2015) · Anaesthesia · doi:10.1111/anae.12923 · Cited by 825
Failure of high-flow nasal cannula therapy may delay intubation and increase mortality
Kang, B. J., Koh, Y., Lim, C.-M., Huh, J. W., Baek, S., Han, M., Seo, H.-S., Suh, H. J., Seo, G. J., Kim, E. Y., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3693-5 · Cited by 657
Hernández, G., Vaquero, C., González, P., Subira, C., Frutos-Vivar, F., Rialp, G., Laborda, C., Colinas, L., Cuena, R., & Fernández, R. (2016) · JAMA · doi:10.1001/jama.2016.2711 · Cited by 551
Sztrymf, B., Messika, J., Bertrand, F., Hurel, D., Leon, R., Dreyfuss, D., & Ricard, J.-D. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2354-6 · Cited by 463
Lee, J. H., Rehder, K. J., Williford, L., Cheifetz, I. M., & Turner, D. A. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2743-5 · Cited by 391
Metadata
- Authors
- Roca, O., Riera, J., Torres, F., & Masclans, J. R.
- Venue
- Respiratory Care
- Publisher
- American Association for Respiratory Care
- Published
- 2010-04-01
- Volume
- 55
- Issue
- 4
- Pages
- 408-413
- ISSN
- 0020-1324 (ISSN-L)
- OpenAlex
- W2183974602
- Cited by
- 302
- References
- 17
- FWCI
- 4.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Flow Oxygen Therapy in Acute Respiratory Failure. https://app.cochat.ai/papers/10.4187/respcare.10550408
- The paper
- Roca, O., Riera, J., Torres, F., & Masclans, J. R. (2010). High-Flow Oxygen Therapy in Acute Respiratory Failure. Respiratory Care. https://doi.org/10.4187/respcare.10550408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.