The DOI matches its Crossref record.
Evaluation of Coronary Venous Anatomy by Multislice Computed Tomography
Open accessAbstract
Background:The coronary venous system is increasingly targeted for pacing in patients with severe heart failure. The recent advancement of Multi-Detector Computed Tomography (MDCT) allows accurate analysis of the coronary arteries, but little data exist on its role in assessing cardiac venous anatomy. The aim of the present study was to investigate the feasibility of using MDCT in evaluating the cardiac venous anatomy in patients with heart disease; Methods and Results: One hundred and eighteen subjects (59 ± 11 years, 100 males) were studied by contrast enhanced 16-slice CT with retrospective ECG-reconstructions. The diameter, length, and angulations of coronary veins were measured from both volume rendered 3-dimensional images and curved multi-planar images. The coronary sinus vein was visualized in all of patients. However, the posterior, postero-lateral, lateral, antero-lateral and anterior veins were found in 71.2%, 50.0%, 65.3%, 9.3% and 96% patients, respectively. Twenty-three (19.5%) subjects had neither postero-lateral nor lateral cardiac veins. The ostial diameter angle of take-off and total length of the postero-lateral and lateral veins ranged from 1.7 - 7.0 mm, 38 - 160 degrees and 2.6 - 10.6 mm, respectively; Conclusions: This study confirms the feasibility of assessing diameter, length, and angulations of coronary veins by MDCT. This non-invasive information should be useful for pre-operative lead placement planning for patients scheduled to have cardiac resynchronization therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Size reduction holds promise to enable pacer implantation in the anterior cardiac vein to eliminate mechanical failure points of existing implantable devices.
“Size reduction holds promise to enable pacer implantation in the anterior cardiac vein (diameter of 3.8 ± 0.7 mm) to eliminate mechanical failure points of existing implantable devices.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [27]
The anterior cardiac vein has a diameter of 3.8 ± 0.7 mm.
“The cardiac pacing unit contains the receiver antenna and is aimed to be implanted inside the anterior cardiac vein (diameter of 3.8 ± 0.7 mm)27.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [27]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 20
- A. F. Kopp, S. Schroeder, A. Kuettner, A. Baumbach, C. Georg, R. Kuzo, et al., “Non-Invasive Coronary Angiography with High Resolution Multidetector-Row Computed Tomography. Results in 102 Patients,” European Heart Journal, Vol. 23, No. 21, 2002, pp. 1714-1725. · DOI
- 10.1016/S0140-6736(00)04058-7 · DOI
- 10.1161/01.CIR.103.21.2535 · DOI
- 10.1161/01.CIR.0000037222.58317.3D · DOI
- 10.1055/s-2002-32227 · DOI
- 10.1055/s-2002-32930 · DOI
- 10.1111/j.1540-8167.1997.tb00853.x · DOI
- 10.1111/j.1540-8167.1997.tb00802.x · DOI
- 10.1111/j.1540-8159.2000.tb00944.x · DOI
- 10.1016/j.jacc.2005.08.032 · DOI
- 10.1016/j.jacc.2003.04.003 · DOI
- 10.1056/NEJMoa013168 · DOI · Paper page
- 10.1111/j.1540-8159.1998.tb01162.x · DOI
- 10.1118/1.1624756 · DOI
- 10.1023/A:1010692103831 · DOI
- 10.1007/s00276-000-0035-1 · DOI
- F. M. Merchant, et al., “Impact of Segmental Left Ventricle Lead Position on Cardiac Resynchronization Therapy Outcomes,” Heart Rhythm, Vol. 7, No. 5, 2010. pp. 639-644. · DOI
- 10.1161/CIRCULATIONAHA.110.000646 · DOI
- 10.1056/NEJM200103223441202 · DOI
- 10.1016/S0003-4975(02)03788-8 · DOI
Cited by
Sorted by citations
Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system
Abiri, P., Abiri, A., Packard, R. R. S., Ding, Y., Yousefi, A., Ma, J., Bersohn, M., Nguyen, K.-L., Markovic, D., Moloudi, S., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-06493-5 · Cited by 68
Metadata
- Authors
- Sun, J. P., Yang, X. S., Lam, Y. Y., Garcia, M. J., & Yu, C. M.
- Affiliations
- Emory University (US)
- Chinese University of Hong Kong (HK)
- Albert Einstein College of Medicine (US)
- Corresponding author
- Yang, Xing Sheng
- Venue
- World Journal of Cardiovascular Surgery
- Publisher
- Scientific Research Publishing, Inc.
- Published
- 2012
- Volume
- 02
- Issue
- 04
- Pages
- 91-95
- ISSN
- 2164-3202 (ISSN-L)
- 2164-3210
- OpenAlex
- W2004904206
- Cited by
- 8
- References
- 0
- Citations by year
- 2021: 1 · 2020: 2 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 1
- FWCI
- 0.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- World Journal of Cardiovascular Surgery (publishedVersion, cc-by)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Coronary Artery Anomalies
- Keywords
- coronary venous anatomy, coronary sinus, coronary veins, multidetector computed tomography, cardiac resynchronization therapy, pacing lead placement, heart failure, noninvasive cardiac imaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review