The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Design principles and performance of bioresorbable polymeric coronary scaffolds
Abstract
AIMS: Bioresorbable polymeric vascular scaffolds may spawn a fourth revolution in percutaneous coronary intervention (PCI) and a novel treatment termed vascular restoration therapy. The principal design considerations for bioresorbable scaffolds are discussed in the context of physiological behaviour using the Bioabsorbable Vascular Solutions (BVS) ABSORB Cohort B scaffold (Abbott Vascular) as an example. METHODS AND RESULTS: The lifecycle of a bioresorbable scaffold is divided into three phases: (1) revascularisation; (2) restoration; and (3) resorption. In the revascularisation phase spanning the first three months after intervention, the bioresorbable scaffold should perform comparably to metallic drug-eluting stents (DES) in terms of deliverability, radial strength, recoil, and neointimal thickening. The ensuing restoration phase is characterised by gradual erosion of radial strength and a loss of structural continuity, where the time scale at which each occurs is related to the hydrolytic degradation rate of the polymer. Natural vasomotion in response to external stimuli is theoretically possible at the end of this phase. Finally, in the resorption phase, the passive implant is systematically resorbed and processed by the body. CONCLUSIONS: Limited clinical data speak to the potential of bioresorbable scaffolds as a new therapy, and future studies will prove critical to inspiring a fourth revolution in PCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of Exercise on Coronary Endothelial Function in Patients with Coronary Artery Disease
Hambrecht, R., Wolf, A., Gielen, S., Linke, A., Hofer, J., Erbs, S., Schoene, N., & Schuler, G. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002173420702 · Cited by 1,340
Constant, J. S., Feng, J. J., Zabel, D. D., Yuan, H., Suh, D. Y., Scheuenstuhl, H., Hunt, T. K., & Hussain, M. Z. (2000) · Wound Repair and Regeneration · doi:10.1111/j.1524-475x.2000.00353.x · Cited by 163
Cited by
Onuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Bio-resorbable polymer stents: a review of material progress and prospects
McMahon, S., Bertollo, N., Cearbhaill, E. D. O., Salber, J., Pierucci, L., Duffy, P., Dürig, T., Bi, V., & Wang, W. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.05.002 · Cited by 194
Development of a flow evolution network model for the stress-strain behavior of poly(L-lactide)
Dreher, M. L., Nagaraja, S., Bergstrom, J., & Hayman, D. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4037071 · Cited by 12
Metadata
- Authors
- Oberhauser, J., Hossainy, S., & Rapoza, R.
- Venue
- EuroIntervention
- Publisher
- Europa Digital & Publishing
- Published
- 2009-12
- Volume
- 5
- Issue
- F
- Pages
- F15-F22
- ISSN
- 1774-024X (ISSN-L)
- OpenAlex
- W2042531431
- Cited by
- 166
- References
- 2
- FWCI
- 5.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design principles and performance of bioresorbable polymeric coronary scaffolds. https://app.cochat.ai/papers/10.4244/eijv5ifa3
- The paper
- Oberhauser, J., Hossainy, S., & Rapoza, R. (2009). Design principles and performance of bioresorbable polymeric coronary scaffolds. EuroIntervention. https://doi.org/10.4244/eijv5ifa3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.