The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Investigation of Head Injury Mechanisms Using Neutral Density Technology and High-Speed Biplanar X-ray
Abstract
The principal focus of this study was the measurement of relative brain motion with respect to the skull using a high-speed, biplanar x-ray system and neutral density targets (NDTs). A suspension fixture was used for testing of inverted, perfused, human cadaver heads. Each specimen was subjected to multiple tests, either struck at rest using a 152-mm-diameter padded impactor face, or stopped against an angled surface from steady-state motion. The impacts were to the frontal and occipital regions. An array of multiple NDTs was implanted in a double-column scheme of 5 and 6 targets, with 10 mm between targets in each column and 80 mm between columns. These columns were implanted in the temporoparietal and occipitoparietal regions. The impacts produced peak resultant accelerations of 10 to 150 g, and peak angular accelerations between 1000 and 8000 rad/s(2). For all but one test, the peak angular speeds ranged from 17 to 22 rad/s. The relative 3D displacements between the skull and the NDTs were analyzed. The localized motions of the brain generally followed loop or figure eight patterns, with peak displacements on the order of +/- 5 mm. These results can be used to further finite-element modeling efforts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pudenz, R. H., & Shelden, C. H. (1946) · Journal of Neurosurgery · doi:10.3171/jns.1946.3.6.0487 · Cited by 255
Shelden, C. H., Pudenz, R. H., Restarski, J. S., & Craig, W. M. (1944) · Journal of neurosurgery · doi:10.3171/jns.1944.1.1.0067 · Cited by 139
Al-Bsharat, A. S., Hardy, W. N., Yang, K. H., Khalil, T. B., Tashman, S., & King, A. I. (1999) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/99sc22 · Cited by 116
Self-citationMcGowan, J. C., McCormack, T. M., Grossman, R. I., Mendon�a, R. G., Chen, X., Berlin, J. A., Meaney, D. F., Xu, B., Cecil, K. M., McIntosh, T. K., et al. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199904)41:4<727::aid-mrm11>3.0.co;2-6 · Cited by 55
Cited by
Predictors for Traumatic Brain Injuries Evaluated through Accident Reconstructions
Kleiven, S. (2007) · SAE Technical Paper Series · doi:10.4271/2007-22-0003 · Cited by 670
Rotational Head Kinematics in Football Impacts: An Injury Risk Function for Concussion
Rowson, S., Duma, S. M., Beckwith, J. G., Chu, J. J., Greenwald, R. M., Crisco, J. J., Brolinson, P. G., Duhaime, A.-C., McAllister, T. W., & Maerlender, A. C. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0392-4 · Cited by 491
Fifty Shades of Brain: A Review on the Mechanical Testing and Modeling of Brain Tissue
Budday, S., Ovaert, T. C., Holzapfel, G. A., Steinmann, P., & Kuhl, E. (2020) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-019-09352-w · Cited by 469
Development of Brain Injury Criteria (BrIC)
Takhounts, E. G., Craig, M. J., Moorhouse, K., McFadden, J., & Hasija, V. (2013) · SAE Technical Paper Series · doi:10.4271/2013-22-0010 · Cited by 455
Recent Advances in Brain Injury Research: A New Human Head Model Development and Validation
Zhang, L., Yang, K. H., Dwarampudi, R., Omori, K., Li, T., Chang, K., Hardy, W. N., Khalil, T. B., & King, A. I. (2001) · SAE Technical Paper Series · doi:10.4271/2001-22-0017 · Cited by 374
Self-citation
Metadata
- Authors
- Hardy, W. N., Foster, C. D., Mason, M. J., Yang, K. H., King, A. I., & Tashman, S.
- Venue
- SAE Technical Paper Series
- Publisher
- SAE International
- Published
- 2001-11-01
- Volume
- 1
- Pages
- 337-68
- ISSN
- 0148-7191 (ISSN-L)
- OpenAlex
- W161308917
- Cited by
- 476
- References
- 4
- FWCI
- 30.90
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.