The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Water Recovery and Oxygen Generation by Electrolysis Aboard the International Space Station
Abstract
The paper deals with the construction and performance data of the service module Zvezda water and oxygen supply systems of the International Space Station (ISS). The performance data at the first 14 months of manned station functioning are provided. The data of humidity condensate and recovered water compositions are reviewed. The water supply and demand balance are analyzed. The system of oxygen generation “Electron-VM” and its functioning results are reviewed. The effective cooperation of the international partners on part of life support is shown.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The Elektron-VM system generates oxygen at a rate of 160 L/h and can support a crew of up to 6 people.”
In the citing paper
“Total power consumption by this system is typically in the range of 288–1344 W but may go up to 1500 W [21].”
Citations
Cites
Samsonov, N. M., Бобе, Л. С., Новіков, В. М., et al. (2000) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2000-01-2517 · Cited by 16
Self-citationWater Recovery and Urine Collection in the Service Module of the International Space Station
Samsonov, N. M., Бобе, Л. С., Новіков, В. М., et al. (2001) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2001-01-2355 · Cited by 13
Self-citationA Regenerative Water Supply System for the ISS Russian Segment
Samsonov, N. M., Бобе, Л. С., Новіков, В. М., et al. (1999) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/1999-01-1951 · Cited by 10
Self-citationSamsonov, N. M., Farafonov, N. S., Gavrilov, L. I., et al. (2000) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2000-01-2356 · Cited by 6
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Keller, R. J., Porter, W., Goli, K., Rosenthal, R., Butler, N., & Jones, J. A. (2021) · Life · doi:10.3390/life11080844 · Cited by 23
“Total power consumption by this system is typically in the range of 288–1344 W but may go up to 1500 W [21].”
Background
Metadata
- Authors
- Samsonov, N. M., Bobe, L. S., Gavrilov, L. I., Korolev, V. P., Novikov, V. M., Farafonov, N. S., Soloukhin, V. A., Romanov, S. J., Andrejchuk, P. O., Protasov, N. N., Rjabkin, A. M., Telegin, A. A., Sinjak, J. E., & Skuratov, V. M.
- Affiliations
- NIICHIMMASH
- S. P. Korolev Rocket and Space Corporation Energia (Russia) (RU)
- RSC Energia
- IMBP
- Venue
- SAE Technical Paper Series
- Publisher
- SAE International
- Published
- 2002-07-15
- Volume
- 1
- ISSN
- 0148-7191 (ISSN-L)
- 2688-3627
- OpenAlex
- W2286697080
- Cited by
- 15
- References
- 4
- Citations by year
- 2025: 1 · 2022: 1 · 2021: 2 · 2017: 1
- FWCI
- 4.77
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- SAE technical papers on CD-ROM/SAE technical paper series (publishedVersion)
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Space Exploration and Technology
- Physical Sciences › Engineering › Aerospace Engineering › Spacecraft Design and Technology
- Social Sciences › Political Science and International Relations › Space exploration and regulation
- Keywords
- water recovery, oxygen production, electrolysis, International Space Station, water supply and demand balance, humidity condensate, life support systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review