Strength and Response of the Human Neck *
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Human volunteers were subjected to static and dynamic environments which produced noninjurious neck responses for neck extension and flexion. Cadavers were used to extend this data into the injury region. Analysis of the data from volunteer and cadaver experiments indicates that equivalent moment at the occipital condyles is the critical injury parameter in extension and in flexion. Static voluntary levels of 17.5 ft lb in extension and 26 ft lb in flexion were attained. A maximum dynamic value of 35 ft lb in extension was reached without injury. In hyperflexion, the chin-chest reaction changes the loading condition at the occipital condyles which resulted in a maximum equivalent moment of 65 ft lb without injury. Noninjurious neck shear and axial forces of 190 lb and 250 lb are recommended based on the static strength data obtained on the volunteers. Neck response envelopes for performance of mechanical necks are given for the extension and flexion modes of the neck.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Study of normal range of motion in the neck utilizing a bubble goniometer.
Buck, C. A., Fb, D., Mj, D., et al. (1959) · PubMed · Cited by 47
Cited by
Nightingale, R. W., Winkelstein, B. A., Knaub, K. E., Richardson, W. J., Luck, J. F., & Myers, B. S. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00037-4 · Cited by 171
Flexion and extension structural properties and strengths for male cervical spine segments
Nightingale, R. W., Carol Chancey, V., Ottaviano, D., Luck, J. F., Tran, L., Prange, M., & Myers, B. S. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.015 · Cited by 153
Metadata
- Authors
- Mertz, H. J., & Patrick, L. M.
- Venue
- SAE Technical Paper Series
- Publisher
- SAE International
- Published
- 1971-02-01
- Volume
- 1
- ISSN
- 0148-7191 (ISSN-L)
- 2688-3627
- OpenAlex
- W1520112212
- Cited by
- 355
- References
- 1
- FWCI
- 8.66
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.