Adsorption of Cu(II) and Cr(VI) ions by chitosan: kinetics and equilibrium studies
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The ability of chitosan as an adsorbent for Cu (II) and Cr (VI) ions in aqueous solution was studied. The experiments were done as batch processes. Equilibrium studies were done on both cross-linked and non-cross-linked chitosan for both metals. Cr (VI) adsorption behaviour could be described using the Langmuir isotherm over the whole concentration range of 10 to 1000 mg·l-1 Cr. The maximum adsorption capacity for both types of chitosan was found to be 78 mg·g-1 for the non-cross-linked chitosan and 50 mg·g-1 for the cross-linked chitosan for the Cr (VI) removal. For the Cu (II) removal the Freundlich isotherm described the experimental data over the whole concentration range of 10 to 1000 mg·l-1 Cu (II). The maximum adsorption capacity for both types of chitosan can be estimated to be greater than 80 mg·g-1. Cr (VI) removal was the highest at pH 5 but pH did not have a large influence on Cu (II). From these results it is clear that the adsorption of heavy metals is possible with chitosan, but that with this method, end concentrations of below 1 mg·l-1 can hardly be obtained. WaterSA Vol.27(1) 2001: 1-8
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adsorption from solution at the solid/liquid interface
Parfitt, G. D., & Rochester, C. H. (1983) · Academic Press eBooks · Cited by 818
Adsorption from solution at the solid/liquid interface
Vincent, B. (1984) · Colloids and Surfaces · doi:10.1016/0166-6622(84)80299-1 · Cited by 591
Preparation and characterization of water-soluble chitin and chitosan derivatives
Sugimoto, M., Morimoto, M., Sashiwa, H., Saimoto, H., & Shigemasa, Y. (1998) · Carbohydrate Polymers · doi:10.1016/s0144-8617(97)00235-x · Cited by 379
THE USE OF SAGO WASTE FOR THE SORPTION OF LEAD AND COPPER
Quek, S. Y., Wase, D. A. J., & Forster, C. F. (1998) · Water SA · Cited by 361
Onsosyen, E., & Skaugrud, O. (1990) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.280490410 · Cited by 298
Uptake of Pb2+ and Cu2+ by novel biopolymers
DEANS, J., & DIXON, B. (1992) · Water Research · doi:10.1016/0043-1354(92)90047-8 · Cited by 245
Transport studies for the sorption of copper ions by chitosan
Findon, A., McKay, G., & Blair, H. S. (1993) · Journal of Environmental Science and Health . Part A: Environmental Science and Engineering and Toxicology · doi:10.1080/10934529309375870 · Cited by 206
Hexavalent chromium interaction with chitosan
Udaybhaskar, P., Iyengar, L., & Rao, A. V. S. P. (1990) · Journal of Applied Polymer Science · doi:10.1002/app.1990.070390322 · Cited by 196
Removal of Cadmium Using Chitosan
Jha, I. N., Iyengar, L., & Rao, A. V. S. P. (1988) · Journal of Environmental Engineering · doi:10.1061/(asce)0733-9372(1988)114:4(962 · Cited by 171
Effect of molecular weight and urea on the conformation of chitosan molecules in dilute solutions
Tsaih, M. L., & Chen, R. H. (1997) · International Journal of Biological Macromolecules · doi:10.1016/s0141-8130(97)01165-3 · Cited by 156
Application of Chitosan Membranes in Separation of Heavy Metal Ions
Kamiński, W., & Modrzejewska, Z. (1997) · Separation Science and Technology · doi:10.1080/01496399708006962 · Cited by 145
Chui, V. W. D., Mok, K. W., Ng, C. Y., Luong, B. P., & Ma, K. K. (1996) · Environment International · doi:10.1016/0160-4120(96)00034-7 · Cited by 129
Equilibrium studies for the sorption of metal ions onto Chitosan
McKay, G., Blair, H. S., & Findon, M. A. (1989) · Cited by 90
Centrifugal casting of ceramic membrane tubes and the coating with chitosan
Steenkamp, G. C., Neomagus, H. W. J. P., Krieg, H. M., & Keizer, K. (2001) · Separation and Purification Technology · doi:10.1016/s1383-5866(01)00069-7 · Cited by 39
Self-citation
Cited by
Babel, S., & Kurniawan, T. A. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2003.10.001 · Cited by 925
Removal of hexavalent chromium-contaminated water and wastewater: A review
Owlad, M., Aroua, M. K., Daud, W. A. W., & Baroutian, S. (2009) · Water, Air, and Soil Pollution · doi:10.1007/s11270-008-9893-7 · Cited by 820
Gerente, C., Lee, V. K. C., Cloirec, P. L., & McKay, G. (2007) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643380600729089 · Cited by 781
Bhatnagar, A., & Sillanpää, M. (2009) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2009.09.003 · Cited by 718
Bhattacharya, A. K., Naiya, T. K., Mandal, S. N., & Das, S. K. (2008) · Chemical Engineering Journal · doi:10.1016/j.cej.2007.05.021 · Cited by 633
Metadata
- Authors
- Schmuhl, R., Krieg, H., & Keizer, K.
- Venue
- Water SA
- Publisher
- Academy of Science of South Africa
- Published
- 2004-04-15
- Volume
- 27
- Issue
- 1
- ISSN
- 0378-4738 (ISSN-L)
- OpenAlex
- W2163980972
- Cited by
- 392
- References
- 14
- FWCI
- 30.59
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.