The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Fiber‐optic oxygen microsensors, a new tool in aquatic biology
Open accessAbstract
A new fiber‐optic oxygen microsensor (microoptrode) based on dynamic fluorescence quenching has been developed to measure oxygen gradients in marine sediments and microbial mats. The microoptrodes are fabricated by immobilizing an oxygen‐quenchable fluorophore at the tapered tip of an optical fiber. A special optoelectronic system has been designed to measure oxygen with these microoptrodes. It is based on small and cheap optical components and can easily be miniaturized for field applications. In contrast to oxygen microelectrodes, the new oxygen microoptrodes are easy to make, do not consume oxygen, and show no stirring dependence of the signal. In addition, they show excellent long‐term stability and storage stability. Hydrogen sulfide, carbon dioxide, and other relevant chemical parameters do not interfere with the measurement. Oxygen profiles in marine sediments obtained from measurements with microoptrodes show good correlation to profiles measured with oxygen microelectrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microelectrodes: Their Use in Microbial Ecology
Revsbech, N. P., & Jørgensen, B. B. (1986) · Advances in Microbial Ecology · doi:10.1007/978-1-4757-0611-6_7 · Cited by 853
Fiber-Optic Chemical Sensors and Biosensors
Wolfbeis, O. S. (2008) · Analytical Chemistry · doi:10.1021/ac800473b · Cited by 571
Distribution of oxygen in marine sediments measured with microelectrodes1
Revsbech, N. P., Sorensen, J., Blackburn, T. H., & Lomholt, J. P. (1980) · Limnology and Oceanography · doi:10.4319/lo.1980.25.3.0403 · Cited by 413
Quenching of luminescence by oxygen
Kautsky, H. (1939) · Transactions of the Faraday Society · doi:10.1039/tf9393500216 · Cited by 387
Revsbech, N. P., & Jorgensen, B. B. (1983) · Limnology and Oceanography · doi:10.4319/lo.1983.28.4.0749 · Cited by 301
A Microelectrode for Measuring Intracellular pH1
Nair, P. K., Spande, J. I., & Whalen, W. J. (1984) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4684-4895-5_85 · Cited by 255
Fibre-optic oxygen sensor with the fluorescence decay time as the information carrier
Lippitsch, M. E., Pusterhofer, J., Leiner, M. J. P., & Wolfbeis, O. S. (1988) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82310-7 · Cited by 255
A microelectrode for measuring intracellular PO2.
Whalen, W. J., Riley, J., & Nair, P. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.5.798 · Cited by 222
Revsbech, N. P., & Ward, D. M. (1983) · Applied and Environmental Microbiology · doi:10.1128/aem.45.3.755-759.1983 · Cited by 195
Some observations on the cerebral cortex with an ultramicro, membrane-covered, oxygen electrode
Silver, I. A. (1965) · Medical & Biological Engineering & Computing · doi:10.1007/bf02476132 · Cited by 151
Cited by
Optical methods for sensing and imaging oxygen: materials, spectroscopies and applications
Wang, X.-D., & Wolfbeis, O. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00039k · Cited by 1,114
Oxygen dynamics of marine sediments
Glud, R. N. (2008) · Marine Biology Research · doi:10.1080/17451000801888726 · Cited by 911
Kristensen, E. (2000) · Hydrobiologia · doi:10.1023/a:1003980226194 · Cited by 642
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Methods for assessing biochemical oxygen demand (BOD): A review
Jouanneau, S., Recoules, L., Durand, M. J., Boukabache, A., Picot, V., Primault, Y., Lakel, A., Sengelin, M., Barillon, B., & Thouand, G. (2014) · Water Research · doi:10.1016/j.watres.2013.10.066 · Cited by 469
Metadata
- Authors
- Klimant, I., Meyer, V., & Kühl, M.
- Venue
- Limnology and Oceanography
- Publisher
- Wiley
- Published
- 1995-09
- Volume
- 40
- Issue
- 6
- Pages
- 1159-1165
- ISSN
- 0024-3590 (ISSN-L)
- 1939-5590
- OpenAlex
- W1969477390
- Cited by
- 379
- References
- 15
- FWCI
- 6.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fiber‐optic oxygen microsensors, a new tool in aquatic biology. https://app.cochat.ai/papers/10.4319/lo.1995.40.6.1159
- The paper
- Klimant, I., Meyer, V., & Kühl, M. (1995). Fiber‐optic oxygen microsensors, a new tool in aquatic biology. Limnology and Oceanography. https://doi.org/10.4319/lo.1995.40.6.1159
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.