Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 273

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Low dissolved DMSP concentrations in seawater revealed by small‐volume gravity filtration and dialysis sampling

Open access
Kiene, Ronald P., Slezak, Doris·2006·Limnology and Oceanography: Methods

Abstract

A variety of filtration and passive dialysis protocols were tested with seawater for determination of the dissolved concentrations of dimethylsulfoniopropionate (DMSPd), a compound originating in the cytosol of many marine phytoplankton. Commonly used sampling procedures, such as in‐line filtration, syringe pressure filtration, and gravity filtration of relatively large‐volume samples (5‐50 mL) through glass fiber filters, caused release of DMSPd from particulate material as evidenced by increasing DMSPd concentrations with volume filtered. Exposure of filters to air at the end of filtration caused particularly severe DMSPd release. Dialysis bags or Slide‐A‐Lyzer dialysis cassettes equilibrated with seawater DMSPd within 4 h, even in polar waters (−1.8 °C), and appeared to give accurate DMSPd concentrations in some circumstances. However, incubation of seawater in laboratory containers (e.g., glass jars) during dialysis sometimes caused artifactual release of DMSPd. We therefore adopted a small‐volume gravity drip filtration (SVDF) procedure, the essential elements of which were: (i) collection of 20 to 50 mL seawater directly from the primary sample container (e.g., Niskin bottle) into a dry, all‐plastic filtration tower; (ii) use of a 47‐mm‐diameter Whatman GF/F filter; (iii) rapid (< 3 min) filtration by gravity (hydrostatic) pressure; (iv) collection of only the first 3.5 mL filtrate for DMSPd analysis; and (v) never exposing the filtered plankton to air. The SVDF procedure appeared to yield the same low DMSPd concentrations as dialysis samplers incubated in the ocean water column. Using the SVDF procedure, DMSPd was found to be < 2.8 nM over a broad range of ocean water types and particulate DMSP concentrations. The maximum DMSPd concentration observed in our study (2.8 nM) was far lower than the reported worldwide average DMSPd concentration of 16.9 nM, raising the possibility that past data collections may have been influenced by filtration artifacts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4319/lom.2006.4.80

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 273

Metadata

Authors
Kiene, R. P., & Slezak, D.
Venue
Limnology and Oceanography: Methods
Publisher
Wiley
Published
2006-04
Volume
4
Issue
4
Pages
80-95
ISSN
1541-5856 (ISSN-L)
OpenAlex
W1495092485
Cited by
273
References
1
FWCI
12.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.