Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 404

The DOI matches its Crossref record.

Post Occupancy Evaluation

·2013·Designing Zero Carbon Buildings Using Dynamic Simulation Methods

Abstract

Post occupancy evaluation (POE) helps us complete the feedback loop in our design, as it gives us comprehensive information about the design and on lessons learnt for future designs. POE can take several forms as follows: • One-off tests • co-heating • air tightness testing • thermal imaging • observation of building envelope • Instrumental monitoring • Experimental measurement of physical parameters of buildings • Energy performance analysis • Troubleshooting of building operation and performance • Calibration of dynamic simulation models • Occupant comfort and behaviour studies ONE-OFF TESTS Co-heating tests Co-heating tests are designed to measure the overall conductive and ventilation heat loss. They are carried out in unoccupied buildings in which a sufficient temperature difference between the inside and the outside is maintained with thermostat controlled portable electric heaters over a period of between one to three weeks (Figure 201). As the building enters into a steady state after a few days of heating, the overall fabric and ventilation heat loss becomes proportional to the heat loss coefficient and inversely proportional to the temperature difference. The heat loss coefficient is calculated by rearranging the heat loss equation: Q = UA × ∆T (51) and solving it for UA as follows: UA = Q ∆T (52) where: UA – overall heat loss coefficient (W/K) Q – heat input (W) ΔT – temperature difference between inside and outside (K) The co-heating test needs to be carried out in winter when a sufficient temperature difference between inside and outside of minimum 10 degrees can be maintained. Fluctuation of external temperature and solar radiation can make the results of the co-heating test unusable. The co-heating test is therefore best conducted during overcast weather conditions with relatively stable outside temperature. In order to minimise fluctuations of temperature differences, the results of co-heating tests are analysed using daily average values of heat input Q and temperature difference ΔT. When the former is plotted against the latter and a regression line fitted to the plotted points, the slope of the line will represent the heat loss coefficient UA (Figure 202). In this particular case related to the building in Figure 212, and unrelated to the specific test in Figure 201, the slope of the line and therefore the overall heat loss coefficient is UA = 249.6 W/K.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4324/9780203135754-30

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 404

Metadata

Venue
Designing Zero Carbon Buildings Using Dynamic Simulation Methods
Publisher
Routledge
Published
2013-07-03
Pages
233-259
OpenAlex
W1516773563
Cited by
404
References
0
FWCI
144.89
Type
book chapter
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Post Occupancy Evaluation. https://app.cochat.ai/papers/10.4324/9780203135754-30
The paper
Post Occupancy Evaluation. (2013). Designing Zero Carbon Buildings Using Dynamic Simulation Methods. https://doi.org/10.4324/9780203135754-30

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.