CoChat

Comparison of Overridden Medication-related Clinical Decision Support in the Intensive Care Unit between a Commercial System and a Legacy System

Open access
Wong, Adrian, Wright, Adam, Seger, Diane L., Amato, Mary G., Fiskio, Julie M., Bates, David · 2017 · Applied Clinical Informatics
Cited by 31

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Summary: Background: Electronic health records (EHRs) with clinical decision support (CDS) have shown to be effective at improving patient safety. Despite this, alerts delivered as part of CDS are overridden frequently, which is of concern in the critical care population as this group may have an increased risk of harm. Our organization recently transitioned from an internally-developed EHR to a commercial system. Data comparing various EHR systems, especially after transitions between EHRs, are needed to identify areas for improvement. Objectives: To compare the two systems and identify areas for potential improvement with the new commercial system at a single institution. Methods: Overridden medication-related CDS alerts were included from October to December of the systems’ respective years (legacy, 2011; commercial, 2015), restricted to three intensive care units. The two systems were compared with regards to CDS presentation and override rates for four types of CDS: drug-allergy, drug-drug interaction (DDI), geriatric and renal alerts. A post hoc analysis to evaluate for adverse drug events (ADEs) potentially resulting from overridden alerts was performed for ‘contraindicated’ DDIs via chart review. Results: There was a significant increase in provider exposure to alerts and alert overrides in the commercial system (commercial: n=5,535; legacy: n=1,030). Rates of overrides were higher for the allergy and DDI alerts (p<0.001) in the commercial system. Geriatric and renal alerts were significantly different in incidence and presentation between the two systems. No ADEs were identified in an analysis of 43 overridden contraindicated DDI alerts. Conclusions: The vendor system had much higher rates of both alerts and overrides, although we did not find evidence of harm in a review of DDIs which were overridden. We propose recommendations for improving our current system which may be helpful to other similar institutions; improving both alert presentation and the underlying knowledge base appear important. Citation: Wong A, Wright A, Seger DL, Amato MG, Fiskio JM, Bates D. Comparison of Overridden Medication-related Clinical Decision Support in the Intensive Care Unit between a Commercial System and a Legacy System. Appl Clin Inform 2017; 8: 866–879 https://doi.org/10.4338/ACI-2017-04-RA-0059

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4338/aci-2017-04-ra-0059

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 31

Metadata

Authors
Wong, A., Wright, A., Seger, D. L., Amato, M. G., Fiskio, J. M., & Bates, D.
Venue
Applied Clinical Informatics
Published
2017-07
Volume
08
Issue
03
Pages
866-879
ISSN
1869-0327 (ISSN-L)
OpenAlex
W2748150666
Cited by
31
References
8
FWCI
3.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.