CoChat

5-aminolevulinic acid induced protoporphyrin IX fluorescence in high-grade glioma surgery

Open access
Hefti, M, Siegner, A, Looser, H, Von, Campe · 2008 · Swiss Medical Weekly
Cited by 68

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Among the factors determining prognosis in patients with malignant glioma, the extent of resection has long been controversial. However, recent data have shown that patients derive a survival benefit from extensive tumour resection. 5-aminolaevulinic acid (5-ALA)-induced fluorescence renders more complete resection possible in malignant glioma. We report on the feasibility of the method in daily clinical practice, the benefits for patients and surgeons, the technical limitations and the methods we have devised of overcoming these limitations. METHODS: We describe our initial experience in 74 cases undergoing gross total resection, partial resection and biopsy. Fluorescence intensity and histological data are analysed, specificity and sensitivity are calculated according to fluorescence intensity, and the pitfalls and limitations are defined. The fluorescence signal was quantified via digital video data and by single photon count. RESULTS: Solid fluorescence signals define tumours with a sensitivity of 0.98 and a specificity of 1.0. Vague fluorescence reduces sensitivity to 0.76 and specificity to 0.85. Limitations of 5-ALAassisted surgery are apparent within the inter-observer interpretation of solid or vague fluorescence, heterogeneity of gliomas, invasion beyond the resection cavity and intercell heterogeneity of porphyrin IX fluorescence. CONCLUSION: 5-ALA-induced PIX fluorescence improves the results in high-grade glioma surgery for gross total resection. Specificity and sensitivity in regions of solid fluorescence are very high. Quantitative analysis of fluorescence intensity corrects the reduced reliability of the method in areas of vague fluorescence and renders gross total resection more feasible without additional risk to the patient. PIX fluorescence is easy to implement in daily neurosurgical practice and side effects are very few. Heterogeneous tumours with lower grade elements and satellite lesions cannot be reliably resected using fluorescence-assisted surgery alone. In these cases the additional use of intra-operatively updated imaging-based neuronavigational methods (MR, ultrasound) is needed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.4414/smw.2008.12077

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 68

Metadata

Authors
Hefti, M., Siegner, A., Looser, H., & Von, C.
Venue
Swiss Medical Weekly
Published
2008-03-22
Volume
138
Issue
1112
Pages
180-180
ISSN
  • 0036-7672 (ISSN-L)
  • 1424-3997
OpenAlex
W2156913009
Cited by
68
References
1
FWCI
0.97
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.