CoChat

A Novel Experimental Approach for Modelling and Control of Pollution Layer in Electrostatic Precipitators

HASKAR, Houari, MILOUA, Farid, BOUZID-DAHO, Abdellatif · 2026 · Electrotehnica, Electronica, Automatica
Cited by 0

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Electrostatic precipitators (ESPs) are among the most widely used devices for removing dust, fumes, and aerosols from gas streams. The efficiency of particle collection depends on several interrelated factors, necessitating continuous monitoring and optimization. Among these, particle resistivity plays a key role in determining ESP performance, especially in relation to the behaviour of the dust layer deposited on the collecting electrode. High-resistivity particles, such as PVC, are difficult to charge and tend to retain their charge upon contact with the grounded electrode. This leads to an accumulation of surface potential and the onset of the back corona phenomenon, which significantly reduces collection efficiency. To optimize filtration, it is essential to maintain a high-intensity electric field that enhances particle charging and collection—particularly for high-resistivity materials—without triggering electrical arcing. This study introduces a novel experimental method for controlling a wire–cylinder type ESP. The method is based on the automatic adjustment of the high-voltage supply using a motorized potentiometer (PM), which ensures the discharge current remains at a predefined set point. The proposed approach allows for the in-situ estimation of the surface potential and resistivity of the pollution layer under electrical discharge conditions, across different particle sizes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.46904/eea.26.74.1.1108008

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 15

  1. "[1] Miloua F., Tilmatine A., Remaoun S.M., Berrached D. and Bengrit M., "Application of electrostatic precipitator in collection of smoke particles from hospital wastes combustion", International Journal of Environmental Studies, vol. 70(4), pp. 527-535, Bejan, 2013, A. Constructal thermodynamics. Constructal Law & Second Law Conference, Parma, pp. S1-S8, 2015. · doi:10.1080/00207233.2013.813715
  2. [2] Yamamoto T., Velkoff H.R., "Electro hydrodynamics in an electrostatic precipitator", Journal of Fluid Mechanics, vol. 108, pp. 1-18, 1981. · doi:10.1017/s002211208100195x
  3. [3] Podlinski J., Niewulis A., Mizeraczyk J. and Atten P., "ESP performance for various dust densities", Journal of Electrostatics, vol. 66(5-6), pp. 246-253, 2008. · DOI
  4. [4] Busby H.T. and Darby K., "Efficiency of electrostatic precipitators as affected by the properties and combustion of coal", J. Inst. Fuel, vol. 36 (5), p. 184, 1963.
  5. [6] Chesmond C., Truce R., "Using Electrostatic Precipitators to Collect Highly Resistive Dust", Institute of Engineers Australia, Queensland Technical Papers, vol. 26 (9), pp. 16-20, 1985.
  6. [7] Adamiak K., Jaworek A., Krupa A., "Deposition efficiency of dust particles on a single, falling and charged water droplet", IEEE Trans. Ind. Appl., 37 (3), pp. 734-750, 2001. · doi:10.1109/28.924754
  7. [8] Xiaodong X., Ying W. and Wangsheng C., "Experimental investigation on the collection of fine dust with high resistivity by a bipolar discharging ESP", in Electrostatic Precipitation, pp. 87-90, Springer, Berlin, Heidelberg, 2009. · doi:10.1007/978-3-540-89251-9_17
  8. [9] Zhu J., Shi Y., Zhang X., Yan H. and Yan K., "Current Density and Efficiency of a Novel Lab ESP for Fine Particles Collection", in Electrostatic Precipitation: 11th International Conference on Electrostatic Precipitation, Hangzhou, 2008, p. 65, Springer Science & Business Media, 2010. · doi:10.1007/978-3-540-89251-9_11
  9. [10] Wenge H., Haowang X., "Non-static Collection Process of the electrostatic Precipitator", in Electrostatic Precipitation, pp. 79-83, Springer, Berlin, Heidelberg, 2009. · DOI
  10. [11] Huang K., "Spark and its effect on electrostatic precipitator", in ICESP X International Conference on Air Pollution Abatement Technologies Future Challenges, pp. 1-12, International Society for Electrostatic Precipitation: Cairns, 2006.
  11. [12] Jaworek A., Czech T., Rajch E. and Lackowski M., "Laboratory studies of back-discharge in fly ash", Journal of Electrostatics, 64(5), pp. 326-337, 2006. · DOI
  12. [13] DESTIARINI KUMARA P.W., 2019, ""Arduino Uno Atmega328-based Line Follower Robot"", Journal Informatika, vol. 5, no. 1, pp. 18-25, ISSN 2407-1730.
  13. [14] Intra P., Limueadphai P. and Tippayawong N., "Particulate emission reduction from biomass burning in small combustion systems with a multiple tubular electrostatic precipitator", Particulate Science and Technology, vol. 28(6), pp. 547-565, 2010. · DOI
  14. [15] Remaoun S.M., Miloua F., Tilmatine A., Hammadi N., Zouzou N. and Dascalescu L., "Optimization of a Cost-Effective Wire Plate-Type ESP for Installation in a Medical Waste Incinerator", IEEE Transactions on Industry Applications, vol. 50(2), pp. 1361-1396, 2014. · doi:10.1109/tia.2013.2272607
  15. [16] Wiggers H., Nasri S., "Measurement of dust resistivity at current densities typically used in electrostatic precipitators", Gefahrstoffe Reinhaltung der Luft, 68(5), pp. 177-181, 2008."

Metadata

Authors
HASKAR, H., MILOUA, F., & BOUZID-DAHO, A.
Venue
Electrotehnica, Electronica, Automatica
Published
2026-03-12
Volume
74
Issue
1
Pages
60-65
ISSN
  • 1582-5175
  • 2392-828X
Cited by
0
References
1

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Novel Experimental Approach for Modelling and Control of Pollution Layer in Electrostatic Precipitators. https://app.cochat.ai/papers/10.46904/eea.26.74.1.1108008
The paper
HASKAR, H., MILOUA, F., & BOUZID-DAHO, A. (2026). A Novel Experimental Approach for Modelling and Control of Pollution Layer in Electrostatic Precipitators. Electrotehnica, Electronica, Automatica. https://doi.org/10.46904/eea.26.74.1.1108008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.