Ocular Shape and Myopia
Open accessThe DOI matches its Crossref record.
Abstract
Introduction: To learn if eye shape might be a useful parameter in refractive research. Materials and Methods: Laboratory research on eye growth mechanisms is summarised. The available clinical literature relating refraction to eye shape and peripheral refraction is critically assessed in the context of the laboratory research on refractive development. Results: Almost all refraction research assesses optical and length parameters exclusively along the visual axis. Contemporary laboratory research demonstrates a remarkable phylogenic conservation of the neural mechanisms regulating refractive development. On-axis image quality regulates central refractive development in animals and probably, to some extent, in humans. Off-axis image quality at the retina depends on anterior segment geometry and optics, and on the 3-dimensional conformation of the retina. In chicks, eye shape is a predictable parameter linked to the underlying neural mechanisms modulating eye development. Based on the sparse clinical literature in human adults and children, the eye shapes induced in chicks are also seen in human subjects in patterns suggesting that eye shape may be a useful parameter in clinical studies. Conclusion: The diverse findings suggest that incorporating the 3-dimensional conformation of the eye into future clinical studies may help resolve many of the ambiguities in contemporary refractive research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Homeostasis of Eye Growth and the Question of Myopia
Wallman, J., & Winawer, J. (2004) · Neuron · doi:10.1016/j.neuron.2004.08.008 · Cited by 1,060
The complex interactions of retinal, optical and environmental factors in myopia aetiology
Flitcroft, D. I. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.06.004 · Cited by 903
Morgan, I., & Rose, K. (2005) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2004.06.004 · Cited by 661
Mutti, D. O., Hayes, J. R., Mitchell, G. L., Jones, L. A., Moeschberger, M. L., Cotter, S. A., Kleinstein, R. N., Manny, R. E., Twelker, J. D., & Zadnik, K. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0562 · Cited by 634
Peripheral Vision Can Influence Eye Growth and Refractive Development in Infant Monkeys
Smith, E. L., Kee, C.-S., Ramamirtham, R., Qiao-Grider, Y., & Hung, L.-F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0445 · Cited by 523
Metadata
- Authors
- Stone, R., & Flitcroft, I.
- Venue
- Annals of the Academy of Medicine, Singapore
- Publisher
- Academy of Medicine, Singapore
- Published
- 2004-01-15
- Volume
- 33
- Issue
- 1
- Pages
- 7-15
- ISSN
- 0304-4602 (ISSN-L)
- OpenAlex
- W4386848639
- Cited by
- 149
- References
- 0
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ocular Shape and Myopia. https://app.cochat.ai/papers/10.47102/annals-acadmedsg.v33n1p7
- The paper
- Stone, R., & Flitcroft, I. (2004). Ocular Shape and Myopia. Annals of the Academy of Medicine, Singapore. https://doi.org/10.47102/annals-acadmedsg.v33n1p7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.