Cited by 3Structural Integrity and Reliability AnalysisCorrosion Behavior and InhibitionEngineering Diagnostics and Reliability

Electric Transmission Tower Corrosion Assessment Using Analytic Hierarchy Process and Health. Index

Open access
Mohd Izhar, Aina Shazwana, Nor Khalid, Nor Hazwani, Usman, Fathoni, Abu Bakar, Mohd Supian, Adriyanshah, Nur Fadilah, Zahari, Hakim·2024·Pertanika Journal of Science and Technology

Abstract

A transmission tower is one of the components in power infrastructure supporting overhead power lines (OHL). Electrical components, structural, and environmental factors are classified as the primary concern as they can cause catastrophic failure in transmission lines. Transmission towers are in various environments, such as coastal and industrial areas, with different atmospheric corrosion levels due to various corrosive pollutants. For maintenance planning, it is essential to consider the effects of corrosion on towers by physical evaluation influenced by atmospheric corrosion. The physical evaluation of each element uses a scoring or rating method ranging from one to five. The Analytic Hierarchy Process (AHP) and Health Index (HI) are used to evaluate the overall condition of the towers. The study discovered that soil corrosivity in coastal areas is high, and atmospheric corrosion is due to chloride content. Although the pollutants in those areas are high and corrosive, the physical evaluation found that most industrial, coastal, and road towers are in good condition at a rating of 4 and 5. The HI result is the dominance of 71% to 85%, which indicates that the towers are in good health.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.47836/pjst.32.4.21

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Publications [11,12,13,14,15,16,17,18,19,20] report the use of the AHP method to prioritize and optimize processes in several areas.

    “Publications [11,12,13,14,15,16,17,18,19,20] report the use of the AHP method to prioritize and optimize processes in several areas.”

    From Multicriteria Methodology for Prioritizing Predictive Maintenance Using RPASs (Drones) with Thermal Cameras on Transmission Lines (2025) · cites this paper as [19]

    The Analytical Hierarchy Process (AHP) section describes using AHP to assign priorities through pairwise comparisons, and Towards Corrosion Hazard Level applies those weights to transmission-tower assessment (page numbers unavailable). This supports the paper as an example of AHP-based prioritization, but our copy does not report that it optimized a process. (LLM, conf=0.82)

    Experimental — accuracy not yet measured
  • The authors of [18,19,20,21] apply AHP to transmission lines, mainly to defects; among these studies, [18,21] are most relevant to the search for prioritization and the establishment of criteria used for transmission lines.

    “Finally, the authors of [18,19,20,21] apply AHP to transmission lines, mainly to defects; among these studies, [18,21] are most relevant to the search for prioritization and the establishment of criteria used for transmission lines.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 44

  1. Adriyanshah, N. F., Khalid, N. H. N., Usman, F., Izhar, A. S. M., Jawas, J. A., & Jalal, W. N. W. (2022). Development of corrosion hazard map in peninsular Malaysia using inverse distance weighting (IDW) interpolation. In M. Awang, L. Ling & S. S. Emamian (Eds.), Advances in Civil Engineering Materials (pp. 225-233). Springer. https://doi.org/10.1007/978-981-16-8667-2_24 · DOI
  2. Arroyave, C., & Morcillo, M. (1995). The effect of nitrogen corrosion oxides in atmospheric. Corrosion Science, 37(2), 293-305. https://doi.org/10.1016/0010-938X(94)00136-T Aina Shazwana Mohd Izhar, Nor Hazwani Nor Khalid, Fathoni Usman, Mohd Supian Abu Bakar, Nur Fadilah Adriyanshah and Hakim Zahari Beynon, M. (2002). DS / AHP method : A mathematical analysis, including an understanding of uncertainty. European Journal of Operational Research, 140(1), 148-164. https://doi.org/10.1016/S0377- 2217(01)00230-2 · DOI
  3. Cardenas, L. A., Alvarez, D. L., Garcia, S. R., & Herrera, F. A. (2019, December 4-6). Overhead lines assessment using health index. [Paper presentation]. FISE-IEEE/CIGRE Conference -Living the energy Transition (FISE/CIGRE), Medellin, Colombi. https://doi.org/10.1109/FISECIGRE48012.2019.8984959 · DOI
  4. Chitpong, J., Suwanasri, C., & Suwanasri, T. (2016, June 28 -July 1). Evaluation criteria for condition and importance assessment of high voltage transmission line. [Paper presentation]. 13th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON), Chiang Mai, Thailang. https://doi.org/10.1109/ECTICon.2016.7561237 · DOI
  5. Corvo, F., Perez, T., Dzib, L. R., Martin, Y., Castañeda, A., Gonzalez, E., & Perez, J. (2008). Outdoor-indoor corrosion of metals in tropical coastal atmospheres. Corrosion Science, 50(1), 220-230. https://doi. org/10.1016/j.corsci.2007.06.011 · DOI
  6. Daneshmand, S. V., Heydari, H., & Shakeri, S. (2011). Multicriteria optimal winding scheme in HTS transformers by analytical hierarchy process. IEEE Transactions on Applied Superconductivity, 21(1), 2-12. https://doi.org/10.1109/TASC.2010.2089051 · DOI
  7. Eyre-Walker, R., Howartht, G., Ahmedv, R., & Lewin, J. (2014, November 27-28). Application of advanced condition assessment and asset management techniques on steel tower overhead line electricity networks. [Paper presentation]. Asset Management Conference, London, United Kingdom. https://doi.org/10.1049/ cp.2014.1047 · DOI
  8. Fathoni, U., Zakaria, C. M., & Rohayu, C. O. (2013). Development of corrosion risk map for Peninsular Malaysia using climatic and air pollution data. IOP Conference Series: Earth and Environmental Science, 16(1), Article 012088. https://doi.org/10.1088/1755-1315/16/1/012088 · DOI
  9. Feliu, S., Morcillo, M., & Chico, B. (1999). Effect of distance from sea on atmospheric corrosion rate. Corrosion, 55(9), 883-891. https://doi.org/10.5006/1.3284045 · DOI
  10. Frost & Sullivan. (2021, August 19). Rising demand for energy efficiency and sustainability boosts the southeast asian integrated facilities management market. https://www.frost.com/news/press-releases/ rising-demand-for-energy-efficiency-and-sustainability-boosts-the-southeast-asian-integrated-facilities- management-market/
  11. Haema, J., & Phadungthin, R. (2012, September 18-20). Condition assessment of the health index for power transformer. [Paper presentation] Power Engineering and Automation Conference, Wuhan, China. https:// doi.org/10.1109/PEAM.2012.6612413 · DOI
  12. Hashim, R., Usman, F., & Baharuddin, I. N. Z. (2019). Determining health index of transmission line asset using condition-based method. Resources, 8(2), 80. https://doi.org/10.3390/resources8020080 · DOI
  13. Hjartarson, T., Jesus, B., Hughes, D. T., & Godfrey, R. M. (2003, September 7-12). Developement of health indices for asset condition assessment. [Paper presentation]. IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495), Dallas, USA. https://doi.org/10.1109/ TDC.2003.1335332 · DOI
  14. Huang, R., An, L., Zhang, R., Wu, J., & Liang, Y. (2018). Research on condition assessment method of transmission tower under the action of strong wind. IOP Conference Series: Materials Science and Engineering, 322(7), Article 072054. https://doi.org/10.1088/1757-899X/322/7/072054 · DOI
  15. Irfan, J., & Handika, P. (2019, October 10-11). Comprehensive calculation of overhead transmission line health index. [Paper presentation]. 11th International Conference on Information Technology and Electrical Engineering (ICITEE), Pattaya, Thailand. https://doi.org/10.1109/ICITEED.2019.8929988 · DOI
  16. Jyothi, B., & Mahesh, S. (2017). Design transmission tower and its foundation. International Journal of Scientific Engineering and Technology Research, 6(6), 1008-1014.
  17. Krishnasamy, R., Shyamala, G., Johnson, S. C., Sabarinathan, K., Sakthivel, S. M., & Rajesh, K. (2020). Performance management of transmission line tower foundations against corrosion by non destructive testing. International Journal of Engineering and Advanced Technology, 9(3), 443-447. https://doi. org/10.35940/ijeat.c4731.029320 · DOI
  18. Kumar, V., Sharma, N., Tiwari, S. K., & Kango, S. (2020). Atmospheric corrosion of materials and their effects on mechanical properties: A brief review. Materials Today: Proceedings, 44, 4677-4681. https:// doi.org/10.1016/j.matpr.2020.10.939 · DOI
  19. Kwan, M. S., Tangang, F. T., & Juneng, L. (2013). Projected changes of future climate extremes in Malaysia. Sains Malaysiana, 42(8), 1051-1058.
  20. Lin, Z. C., & Yang, C. B. (1996). Evaluation of machine selection by the AHP method. Journal of Material Processing Energy, 57(3-4), 253-258. https://doi.org/10.1016/0924-0136(95)02076-4 · DOI
  21. Manninen, H., Ramlal, C. J., Singh, A., Rocke, S., Kilter, J., & Landsberg, M. (2021). Toward automatic condition assessment of high-voltage transmission infrastructure using deep learning techniques. International Journal of Electrical Power and Energy Systems, 128, Article 106726. https://doi. org/10.1016/j.ijepes.2020.106726 · DOI
  22. Naranpanawe, L., Ma, H., Saha, T. K., Lee, C., & Ghosal, A. (2020). A practical health index for overhead conductors : Experience from Australian distribution networks. IEEE Access, 8, 218863-218873. https:// doi.org/10.1109/ACCESS.2020.3042486 · DOI
  23. Pongsaksawad, W., Klomjit, P., Khamsuk, P., Sorachot, S., Pålsson, N. S., & Viyanit, E. (2021). Chloride distribution model and corrosion map of structural steels for tropical climate in Thailand. Science of the Total Environment, 787, Article 147465. https://doi.org/10.1016/j.scitotenv.2021.147465 · DOI
  24. Rajesh, G., & Malliga, P. (2013). Supplier selection based on AHP QFD methodology. Procedia Engineering, 64, 1283-1292. https://doi.org/10.1016/j.proeng.2013.09.209 · DOI
  25. A.RI.EL: A structural integrity condition based method for renewal assessment of pylons in overhead transmission lines. [Paper presentation]. AEIT International Annual Conference, Bari, Italy.
  26. Rodger, J., Bartlett, S., & Atrens, A. (2017). Corrosion of the galvanising of galvanised-Steel electricity transmission towers. Materials and Corrosion, 68(8), 902-910. https://doi.org/10.1002/maco.201609351 · DOI
  27. Saaty, T. L. (2008). Decision making with the analytic hierarchy process. International Journal of Services Sciences, 1(1), 83-98. https://doi.org/10.1504/IJSSCI.2008.017590 · DOI · Paper page
  28. Aina Shazwana Mohd Izhar, Nor Hazwani Nor Khalid, Fathoni Usman, Mohd Supian Abu Bakar, Nur Fadilah Adriyanshah and Hakim Zahari Saaty, T. L. (1977). A scaling method for priorities in hierarchical structures. Journal of Mathematical Psychology, 15(3), 234-281. https://doi.org/10.1016/0022-2496(77)90033-5 · DOI
  29. Sing, L. K., Yahaya, N., Othman, S. R., Fariza, S. N., & Noor, N. M. (2013). The relationship between soil resistivity and corrosion growth in tropical region. Journal of Corrosion Science and Engineering, 16, 1-11.
  30. Soufeiani, L., Foliente, G., Nguyen, K. T. Q., & Nicolas, R. S. (2020). Corrosion protection of steel elements in façade systems -A review. Journal of Building Engineering, 32, Article 101759. https://doi.org/10.1016/j. jobe.2020.101759 · DOI
  31. Syed, S. (2006). Atmospheric corrosion of materials. Emirates Journal for Engineering Research, 11(1), 1-24.
  32. Tanaka, H., Tsukao, S., Yamashita, D., Niimura, T., & Yokoyama, R. (2010). Multiple criteria assessment of substation conditions by pair-wise comparison of analytical hierarchy process. IEEE Transactions on Power Delivery, 25(4), 3017-3023. https://doi.org/10.1109/TPWRD.2010.2048437 · DOI
  33. Tang, K. H. D. (2019). Climate change in Malaysia: Trends, contributors, impacts, mitigation and adaptations. Science of the Total Environment, 650, 1858-1871. https://doi.org/10.1016/j.scitotenv.2018.09.316 · DOI
  34. Triantaphyllou, E., & Mann, S. H. (1995). Using the analytic hierarchy process for decision making in engineering applications: Some challenges. International Journal of Industrial Engineering: Applications and Practice, 2(1), 35-44.
  35. Tsimberg, Y., Lotho, K., Dimnik, C., Wrathall, N., & Mogilevsky, A. (2014, April 14-17). Determining transmission line conductor condition and remaining life. [Paper presentation]. IEEE PES T&D Conference and Exposition, Chicago, USA. https://doi.org/10.1109/tdc.2014.6863242 · DOI
  36. Usman, F., Khalid, N. H. N., Omar, R. C., & Jawas, M. J. A. (2021). Atmospheric corrosion map for service life prediction of lattice steel tower using air pollution data and meteorological data. AIP Conference Proceedings, 2339(1), Article 020189. https://doi.org/10.1063/5.0044393 · DOI
  37. Usman, F., & Khalid, N. H. N. (2021). Predicting remaining life of lattice steel transmission tower based on condition assessment and corrosion hazard data. E3S Web of Conferences, 325, Article 01011. https:// doi.org/10.1051/e3sconf/202132501011 · DOI
  38. Usman, F., & Resdiansyah, M. (2008, June 16-20). Service life prediction of building components. International Conference on Construction and Building Technology (ICCBT), Kuala Lumpur, Malaysia
  39. Velásquez, R. M. A., & Lara, J. V. M. (2018, September 19-21). Methodology for overhead line conductor remaining life aging infrastructure and asset management. [Paper presentation]. IEEE PES Transmission & Distribution Conference and Exhibition -Latin America (T&D-LA), Lima, Peru. https://doi.org/10.1109/ TDC-LA.2018.8511752. · DOI
  40. Wang, J., Liu, P., Ren, K., Wang, X., & Xu, S. (2022). Corrosion of steel materials in four environmental conditions. Journal of Physics: Conference Series, 2390, Article 012002. https://doi.org/10.1088/1742- 6596/2390/1/012002 · DOI
  41. Waters, F. O. (1952). Soil resistivity measurements for corrosion control. Corrosion-National Association of Corrosion Engineers, 8(12), 407-409. https://doi.org/10.5006/0010-9312-8.12.407 · DOI
  42. Wuller, A. I., & Pharmatrisanti, A. (2012, September 23-27). Transmission line assessment. [Paper presentation]. IEEE International Conference on Condition Monitoring and Diagnosis, Bali Indonesia. https://doi. org/10.1109/CMD.2012.6416418 · DOI
  43. Zhang, D., Li, W., & Xiong, X. (2014). Overhead line preventive maintenance strategy based on condition monitoring and system reliability assessment. IEEE Transactions on Power Systems, 29(4), 1839-1846. https://doi.org/10.1109/TPWRS.2013.2295379 · DOI
  44. Zhang, T., Liu, L., Wiliem, A., Connor, S., Ilich, Z., Van Der Draai, E., & Lovell, B. (2019, December 2-4). Deep corrosion assessment for electrical transmission towers. [Paper presentation]. Digital Image Computing: Techniques and Applications (DICTA), Perth, Australia. https://doi.org/10.1109/ DICTA47822.2019.8945905 · DOI

Cited by

Sorted by citations

Authors
Mohd Izhar, A. S., Nor Khalid, N. H., Usman, F., Abu Bakar, M. S., Adriyanshah, N. F., & Zahari, H.
Affiliations
  • Universiti Tenaga Nasional (MY)
  • Tenaga Nasional Berhad (Malaysia) (MY)
Venue
Pertanika Journal of Science and Technology
Published
2024-07-22
Volume
32
Issue
4
Pages
1855-1873
ISSN
  • 0128-7680 (ISSN-L)
  • 2231-8526
OpenAlex
W4400839856
Cited by
3
References
0
Citations by year
2026: 1 · 2025: 2
FWCI
0.40
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
Pertanika journal of science & technology (publishedVersion, cc-by-nc-nd)
Funders
  • Tenaga Nasional Berhad
  • Universiti Tenaga Nasional
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Structural Integrity and Reliability Analysis
  • Physical Sciences › Materials Science › Materials Chemistry › Corrosion Behavior and Inhibition
  • Physical Sciences › Engineering › Mechanics of Materials › Engineering Diagnostics and Reliability
Keywords
transmission towers, atmospheric corrosion, health indicators, analytic hierarchy process, overhead power lines, chloride contamination, littoral zone, industrial pollution, maintenance planning

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review