The DOI matches its DataCite record; the references it cites are not checked yet.
A Novel Sensorised Insole for Sensing Feet Pressure Distributions
Abstract
Wearable sensors are gaining in popularity because they enable outdoor experimental monitoring. This paper presents a cost-effective sensorised insole based on a mesh of tactile capacitive sensors. Each sensor's spatial resolution is about 4 taxels/cm^2 in order to have an accurate reconstruction of the contact pressure distribution. As a consequence, the insole provides information such as contact forces, moments, and center of pressure. To retrieve this information, a calibration technique that fuses measurements from a vacuum chamber and shoes equipped with force/torque sensors is proposed. The validation analysis shows that the best performance achieved a root mean square error (RMSE) of about 7 N for the contact forces and 2 N m for the contact moments when using the force/torque shoe data as ground truth. Thus, the insole may be an alternative to force/torque sensors for certain applications, with a considerably more cost-effective and less invasive hardware.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Metadata
- Authors
- Sorrentino, I., Chavez, F. J. A., Latella, C., Fiorio, L., Traversaro, S., Rapetti, L., Tirupachuri, Y., Guedelha, N., Maggiali, M., Dussoni, S., Metta, G., & Pucci, D.
- Venue
- arXiv
- Publisher
- arXiv
- Published
- 2019
- arXiv
- 1910.06370
- Type
- Preprint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Sensorised Insole for Sensing Feet Pressure Distributions. https://app.cochat.ai/papers/10.48550/arxiv.1910.06370
- The paper
- Sorrentino, I., Chavez, F. J. A., Latella, C., Fiorio, L., Traversaro, S., Rapetti, L., Tirupachuri, Y., Guedelha, N., Maggiali, M., Dussoni, S., Metta, G., & Pucci, D. (2019). A Novel Sensorised Insole for Sensing Feet Pressure Distributions. arXiv. https://doi.org/10.48550/arxiv.1910.06370
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.