Deep Generative Model-Aided Power System Dynamic State Estimation and Reconstruction with Unknown Control Inputs or Data Distributions
The DOI matches its DataCite record.
Abstract
Fast and robust dynamic state estimation (DSE) is essential for accurately capturing the internal dynamic processes of power systems, and it serves as the foundation for reliably implementing real-time dynamic modeling, monitoring, and control applications. Nonetheless, on one hand, traditional DSE methods based on Kalman filtering or particle filtering have high accuracy requirements for system parameters, control inputs, phasor measurement unit (PMU) data, and centralized DSE communication. Consequently, these methods often face accuracy bottlenecks when dealing with structural or system process errors, unknown control vectors, PMU anomalies, and communication contingencies. On the other hand, deep learning-aided DSE, while parameter-free, often suffers from generalization issues under unforeseen operating conditions. To address these challenges, this paper proposes an effective approach that leverages deep generative models from AI-generated content (AIGC) to assist DSE. The proposed approach employs an encoder-decoder architecture to estimate unknown control input variables, a robust encoder to mitigate the impact of bad PMU data, and latent diffusion model to address communication issues in centralized DSE. Additionally, a lightweight adaptor is designed to quickly adjust the latent vector distribution. Extensive experimental results on the IEEE 39-bus system and the NPCC 140-bus system demonstrate the effectiveness and superiority of the proposed method in addressing DSE modeling imperfection, measurement uncertainties, communication contingencies, and unknown distribution challenges, while also proving its ability to reduce data storage and communication resource requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Similarly, generative AI has been applied to support power system operation through state estimation under partial, noisy, or missing measurement conditions by reconstructing latent system variables and estimating unknown control inputs, improving the completeness and reliability of estimated system states even in data-sparse scenarios (He et al. 2020;Pei et al. 2025).”
From Generative AI and LLM applications in renewable energy and smart grids: a systematic review for the sustainable energy transition (2026) · cites this paper as Pei et al. 2025
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cali, U., Halden, U., Andoni, M., Catak, F. O., Chen, S., Couraud, B., Kantar, E., Knapper, S., Kucukdemiral, I., Kusetogullari, H., et al. (2026) · Artificial Intelligence Review · doi:10.1007/s10462-026-11545-2 · Cited by 18
Metadata
- Authors
- Pei, J., Wang, P., Wang, J., & Shi, D.
- Venue
- arXiv
- Publisher
- arXiv
- Published
- 2025
- arXiv
- 2501.02928
- References
- 0
- Type
- Preprint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deep Generative Model-Aided Power System Dynamic State Estimation and Reconstruction with Unknown Control Inputs or Data Distributions. https://app.cochat.ai/papers/10.48550/arxiv.2501.02928
- The paper
- Pei, J., Wang, P., Wang, J., & Shi, D. (2025). Deep Generative Model-Aided Power System Dynamic State Estimation and Reconstruction with Unknown Control Inputs or Data Distributions. arXiv. https://doi.org/10.48550/arxiv.2501.02928
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.