Development of a Hybrid Scintillator Strip-Drift Tube Muon Detector for the FCC-ee
The DOI matches its DataCite record; the references it cites are not checked yet.
Abstract
The Future Circular Collider (FCC-ee) is a proposed high-luminosity $e^+e^-$ collider for precision measurements at the electroweak, Higgs, and top-quark energy scales. A high-performance, cost-effective muon system is essential for muon identification, triggering, momentum measurement, and long-lived particle detection. We present the R&D of a hybrid muon detector concept combining fast extruded plastic scintillator strips with precision drift tubes. The scintillator strips were produced at Fermilab, while detector prototypes with SiPM readout and pressurized drift tubes were designed, constructed, and integrated at the University of Michigan. The hybrid detector was tested at the CERN test beam facility in 2025 and 2026. The scintillator strips achieved a position resolution of 1.6 mm and a time resolution of approximately 350 ps, while the drift tubes provided a single-hit spatial resolution better than 100 $μ$m. These results demonstrate the feasibility of a high-performance hybrid muon spectrometer for the FCC-ee.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Metadata
- Authors
- Ge, J.
- Venue
- arXiv
- Publisher
- arXiv
- Published
- 2026
- arXiv
- 2611.29331
- Type
- Preprint
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Hybrid Scintillator Strip-Drift Tube Muon Detector for the FCC-ee. https://app.cochat.ai/papers/10.48550/arxiv.2611.29331
- The paper
- Ge, J. (2026). Development of a Hybrid Scintillator Strip-Drift Tube Muon Detector for the FCC-ee. arXiv. https://doi.org/10.48550/arxiv.2611.29331
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.