Corrosion of Alloy 625 in Aqueous Solutions Containing Chloride and Oxygen
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Alloy 625 (UNS N06625) is used frequently as a reactor material for the oxidation of hazardous organic wastes in supercritical water (supercritical water oxidation [SCWO]). In the presence of chloride (Cl–) and oxygen (O2), all Ni-based alloys corrode fast in high-temperature, subcritical water. High-pressure, high-temperature-resistant tube reactors made of alloy 625 were used as specimens. Coupons were exposed simultaneously inside the test tubes. Experimental conditions included temperatures up to 500°C and pressures up to 38 MPa. Pitting corrosion was observed at temperatures above ≈ 130°C to 215°C. At higher temperatures (up to the critical temperature of water), transpassive dissolution dominated. Under certain conditions, transgranular stress corrosion cracking (TGSCC) appeared in the transition zone between the passive and transpassive regions leading to premature failure of the test reactors. Parts of the corrosion products were insoluble in supercritical water and formed thick layers in the supercritical part of the reactor. Underneath these layers, very little intergranular corrosion (IGC) occurred. In neutral or alkaline solutions and in deaerated hydrochloric acid (HCl), corrosion rates of transpassive dissolution decreased drastically.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Corrosion in Supercritical Water Oxidation Systems: A Phenomenological Analysis
Kriksunov, L. B., & Macdonald, D. D. (1995) · Journal of The Electrochemical Society · doi:10.1149/1.2048464 · Cited by 126
Cited by
Corrosion in high-temperature and supercritical water and aqueous solutions: a review
Kritzer, P. (2004) · The Journal of Supercritical Fluids · doi:10.1016/s0896-8446(03)00031-7 · Cited by 660
Self-citationAn assessment of supercritical water oxidation (SCWO)
Kritzer, P., & Dinjus, E. (2001) · Chemical Engineering Journal · doi:10.1016/s1385-8947(00)00255-2 · Cited by 383
Self-citationSupercritical water oxidation—Current status of full-scale commercial activity for waste destruction
Marrone, P. A. (2013) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2012.12.020 · Cited by 232
Corrosion control methods in supercritical water oxidation and gasification processes
Marrone, P. A., & Hong, G. T. (2009) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2009.08.001 · Cited by 223
Analytical extractions with water at elevated temperatures and pressures
Kronholm, J., Hartonen, K., & Riekkola, M.-L. (2007) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.03.004 · Cited by 177
Metadata
- Authors
- Kritzer, P., Boukis, N., & Dinjus, E.
- Venue
- Corrosion
- Published
- 1998-10-01
- Volume
- 54
- Issue
- 10
- Pages
- 824-834
- ISSN
- 0010-9312 (ISSN-L)
- 1938-159X
- OpenAlex
- W2141033855
- Cited by
- 112
- References
- 1
- FWCI
- 17.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corrosion of Alloy 625 in Aqueous Solutions Containing Chloride and Oxygen. https://app.cochat.ai/papers/10.5006/1.3284802
- The paper
- Kritzer, P., Boukis, N., & Dinjus, E. (1998). Corrosion of Alloy 625 in Aqueous Solutions Containing Chloride and Oxygen. Corrosion. https://doi.org/10.5006/1.3284802
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.