Department of Radiology, McMaster University School of Medicine, Hamilton, ON, Canada, Midia, Mehran, Devang, Odedra, Department of Radiology, McMaster University School of Medicine, Hamilton, ON, Canada, Shuster, Anatoly, Department of Radiology, Thunder Bay Health Sciences, Thunder Bay, ON, Canada, Midia, Ramin, St Francis Health, Topeka, Kansas, USA, Muir, Jeffrey, Motion Research, Ancaster, ON, Canada · 2019 · Diagnostic and Interventional Radiology
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: Percutaneous tissue biopsy is a mainstay of diagnostic and interventional radiology, providing a minimally invasive method for diagnosing malignant and benign disease. The purpose of this review was to collect and summarize the best available evidence regarding the risk factors associated with bleeding complications in image-guided liver biopsy. METHODS: A literature review was performed, searching Medline, EMBASE, CINAHL, the Cochrane Library, the National Institute for Health and Care Excellence (NICE) and Canadian Agency for Drugs and Technology in Health (CADTH) databases for any studies evaluating bleeding complications in image-guided liver biopsy. A total of 68 articles, published between January 1994 and April 2015, were reviewed in full, with 34 ultimately eligible for inclusion in the review. RESULTS: Bleeding of any kind occurred in up to 10.9% of image-guided liver biopsies, with major bleeding episodes ranging from 0.1% to 4.6% and minor bleeding events occurring in up to 10.9% of biopsies. The overall rate of bleeding was, however, found to be less than 2%. Several risk factors (patient, operator, and procedure-related) were identified as potentially indicative of an increased risk of post-biopsy bleeding. Patient-related risk factors included patient age (>50 years or <2 years), inpatient status (8/12 vs. 4/12, P < 0.001), comorbidities and/or concurrent diagnoses and coagulation status (rate of bleeding was 3.3% for international normalized ratio [INR] 1.2-1.5 vs. 7.1% for INR >1.5, P < 0.001). There was no consensus on impact of operator experience (>200 biopsies/year vs. <50/year) on post-biopsy bleeding rate. Procedure-related risk factors included needle size (cutting biopsy vs. fine needle aspiration, P < 0.001) and the presence of a patent track on post-biopsy ultrasound (P < 0.001). Lastly there was no difference found between targeted vs. nontargeted biopsies and number of needle passes. CONCLUSION: Reported rate of post-biopsy bleeding ranges between 0% and 10.9%, although the vast majority of studies reported bleeding rates under 2%. Several patient, operator, and procedure-related risk factors are associated with a higher risk of bleeding following liver biopsy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5152/dir.2018.17525

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Department of Radiology, M. U. S. O. M., Midia, M., Devang, O., Department of Radiology, M. U. S. O. M., Shuster, A., Department of Radiology, T. B. H. S., Midia, R., St Francis Health, T., Muir, J., & Motion Research, A.
Venue
Diagnostic and Interventional Radiology
Published
2019-01-18
Volume
25
Issue
1
Pages
71-80
ISSN
  • 1300-4360 (ISSN-L)
  • 1305-3612
OpenAlex
W2911222992
Cited by
160
References
1
FWCI
10.43
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.