Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 340

The DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.

Daytime atmospheric oxidation capacity in four Chinese megacities during the photochemically polluted season: a case study based on box model simulation

Open access
Tan, Zhaofeng, Lu, Keding, Jiang, Meiqing, Su, Rong, Wang, Hongli, Lou, Shengrong, Fu, Qingyan, Zhai, Chongzhi, Tan, Qinwen, Yue, Dingli, Chen, Duohong, Wang, Zhanshan, Xie, Shaodong, Zeng, Limin, Zhang, Yuanhang·2019·Atmospheric Chemistry and Physics

Abstract

Abstract. Atmospheric oxidation capacity is the basis for converting freshly emitted substances into secondary products and is dominated by reactions involving hydroxyl radicals (OH) during daytime. In this study, we present in situ measurements of ROx radical (hydroxy OH, hydroperoxy HO2, and organic peroxy RO2) precursors and products; the measurements are carried out in four Chinese megacities (Beijing, Shanghai, Guangzhou, and Chongqing) during photochemically polluted seasons. The atmospheric oxidation capacity is evaluated using an observation-based model and radical chemistry precursor measurements as input. The radical budget analysis illustrates the importance of HONO and HCHO photolysis, which account for ∼50 % of the total primary radical sources. The radical propagation is efficient due to abundant NO in urban environments. Hence, the production rate of secondary pollutants, that is, ozone (and fine-particle precursors (H2SO4, HNO3, and extremely low volatility organic compounds, ELVOCs) is rapid, resulting in secondary air pollution. The ozone budget demonstrates its high production in urban areas; also, its rapid transport to downwind areas results in rapid increase in local ozone concentrations. The O3–NOx–VOC (volatile organic compound) sensitivity tests show that ozone production is VOC-limited and that alkenes and aromatics should be mitigated first for ozone pollution control in the four studied megacities. In contrast, NOx emission control (that is, a decrease in NOx) leads to more severe ozone pollution. With respect to fine-particle pollution, the role of the HNO3–NO3 partitioning system is investigated using a thermal dynamic model (ISORROPIA 2). Under high relative humidity (RH) and ammonia-rich conditions, nitric acid converts into nitrates. This study highlights the efficient radical chemistry that maintains the atmospheric oxidation capacity in Chinese megacities and results in secondary pollution characterized by ozone and fine particles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5194/acp-19-3493-2019

Cites

66 of 66 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 66 references

Cited by

See all 340

Metadata

Authors
Tan, Z., Lu, K., Jiang, M., Su, R., Wang, H., Lou, S., Fu, Q., Zhai, C., Tan, Q., Yue, D., Chen, D., Wang, Z., Xie, S., Zeng, L., & Zhang, Y.
Venue
Atmospheric Chemistry and Physics
Published
2019-03-20
Volume
19
Issue
6
Pages
3493-3513
ISSN
  • 1680-7316 (ISSN-L)
  • 1680-7324
OpenAlex
W2922591727
Cited by
340
References
66
FWCI
16.55
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Daytime atmospheric oxidation capacity in four Chinese megacities during the photochemically polluted season: a case study based on box model simulation. https://app.cochat.ai/papers/10.5194/acp-19-3493-2019
The paper
Tan, Z., Lu, K., Jiang, M., Su, R., Wang, H., Lou, S., Fu, Q., Zhai, C., Tan, Q., Yue, D., Chen, D., Wang, Z., Xie, S., Zeng, L., & Zhang, Y. (2019). Daytime atmospheric oxidation capacity in four Chinese megacities during the photochemically polluted season: a case study based on box model simulation. Atmospheric Chemistry and Physics. https://doi.org/10.5194/acp-19-3493-2019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.