Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 418

The DOI matches its Crossref record.

Field evaluation of low-cost particulate matter sensors in high- and low-concentration environments

Open access
Zheng, Tongshu, Bergin, Michael H., Johnson, Karoline K., Tripathi, Sachchida N., Shirodkar, Shilpa, Landis, Matthew S., Sutaria, Ronak, Carlson, David E.·2018·Atmospheric Measurement Techniques

Abstract

Abstract. Low-cost particulate matter (PM) sensors are promising tools for supplementing existing air quality monitoring networks. However, the performance of the new generation of low-cost PM sensors under field conditions is not well understood. In this study, we characterized the performance capabilities of a new low-cost PM sensor model (Plantower model PMS3003) for measuring PM2.5 at 1 min, 1 h, 6 h, 12 h, and 24 h integration times. We tested the PMS3003 sensors in both low-concentration suburban regions (Durham and Research Triangle Park (RTP), NC, US) with 1 h PM2.5 (mean ± SD) of 9±9 and 10±3 µg m−3, respectively, and a high-concentration urban location (Kanpur, India) with 1 h PM2.5 of 36±17 and 116±57 µg m−3 during monsoon and post-monsoon seasons, respectively. In Durham and Kanpur, the sensors were compared to a research-grade instrument (environmental β attenuation monitor, E-BAM) to determine how these sensors perform across a range of PM2.5 concentrations and meteorological factors (e.g., temperature and relative humidity, RH). In RTP, the sensors were compared to three Federal Equivalent Methods (FEMs) including two Teledyne model T640s and a Thermo Scientific model 5030 SHARP to demonstrate the importance of the type of reference monitor selected for sensor calibration. The decrease in 1 h mean errors of the calibrated sensors using univariate linear models from Durham (201 %) to Kanpur monsoon (46 %) and post-monsoon (35 %) seasons showed that PMS3003 performance generally improved as ambient PM2.5 increased. The precision of reference instruments (T640: ±0.5 µg m−3 for 1 h; SHARP: ±2 µg m−3 for 24 h, better than the E-BAM) is critical in evaluating sensor performance, and β-attenuation-based monitors may not be ideal for testing PM sensors at low concentrations, as underscored by (1) the less dramatic error reduction over averaging times in RTP against optically based T640 (from 27 % for 1 h to 9 % for 24 h) than in Durham (from 201 % to 15 %); (2) the lower errors in RTP than the Kanpur post-monsoon season (from 35 % to 11 %); and (3) the higher T640–PMS3003 correlations (R2≥0.63) than SHARP–PMS3003 (R2≥0.25). A major RH influence was found in RTP (1 h RH =64±22 %) due to the relatively high precision of the T640 measurements that can explain up to ∼30 % of the variance in 1 min to 6 h PMS3003 PM2.5 measurements. When proper RH corrections are made by empirical nonlinear equations after using a more precise reference method to calibrate the sensors, our work suggests that the PMS3003 sensors can measure PM2.5 concentrations within ∼10 % of ambient values. We observed that PMS3003 sensors appeared to exhibit a nonlinear response when ambient PM2.5 exceeded ∼125 µg m−3 and found that the quadratic fit is more appropriate than the univariate linear model to capture this nonlinearity and can further reduce errors by up to 11 %. Our results have substantial implications for how variability in ambient PM2.5 concentrations, reference monitor types, and meteorological factors can affect PMS3003 performance characterization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5194/amt-11-4823-2018

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 418

Metadata

Authors
Zheng, T., Bergin, M. H., Johnson, K. K., Tripathi, S. N., Shirodkar, S., Landis, M. S., Sutaria, R., & Carlson, D. E.
Venue
Atmospheric Measurement Techniques
Published
2018-08-22
Volume
11
Issue
8
Pages
4823-4846
ISSN
  • 1867-1381 (ISSN-L)
  • 1867-8548
OpenAlex
W2801553349
Cited by
418
References
0
FWCI
21.83
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Field evaluation of low-cost particulate matter sensors in high- and low-concentration environments. https://app.cochat.ai/papers/10.5194/amt-11-4823-2018
The paper
Zheng, T., Bergin, M. H., Johnson, K. K., Tripathi, S. N., Shirodkar, S., Landis, M. S., Sutaria, R., & Carlson, D. E. (2018). Field evaluation of low-cost particulate matter sensors in high- and low-concentration environments. Atmospheric Measurement Techniques. https://doi.org/10.5194/amt-11-4823-2018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.