Detection of HO 2 by laser-induced fluorescence: calibration and interferences from RO 2 radicals
Open accessAbstract
Abstract. HO2 concentration measurements are widely accomplished by chemical conversion of HO2 to OH including reaction with NO and subsequent detection of OH by laser-induced fluorescence. RO2 radicals can be converted to OH via a similar radical reaction sequence including reaction with NO, so that they are potential interferences for HO2 measurements. Here, the conversion efficiency of various RO2 species to HO2 is investigated. Experiments were conducted with a radical source that produces OH and HO2 by water photolysis at 185 nm, which is frequently used for calibration of LIF instruments. The ratio of HO2 and the sum of OH and HO2 concentrations provided by the radical source was investigated and was found to be 0.50 ± 0.02. RO2 radicals are produced by the reaction of various organic compounds with OH in the radical source. Interferences via chemical conversion from RO2 radicals produced by the reaction of OH with methane and ethane (H-atom abstraction) are negligible consistent with measurements in the past. However, RO2 radicals from OH plus alkene- and aromatic-precursors including isoprene (mainly OH-addition) are detected with a relative sensitivity larger than 80 % with respect to that for HO2 for the configuration of the instrument with which it was operated during field campaigns. Also RO2 from OH plus methyl vinyl ketone and methacrolein exhibit a relative detection sensitivity of 60 %. Thus, previous measurements of HO2 radical concentrations with this instrument were biased in the presence of high RO2 radical concentrations from isoprene, alkenes or aromatics, but were not affected by interferences in remote clean environment with no significant emissions of biogenic VOCs, when the OH reactivity was dominated by small alkanes. By reducing the NO concentration and/or the transport time between NO addition and OH detection, interference from these RO2 species are suppressed to values below 20 % relative to the HO2 detection sensitivity. The HO2 conversion efficiency is also smaller by a factor of four, but this is still sufficient for atmospheric HO2 concentration measurements for a wide range of conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nighttime radical observations and chemistry
Brown, S. S., & Stutz, J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35181a · Cited by 637
Tropospheric OH and HO2 radicals: field measurements and model comparisons
Stone, D., Whalley, L. K., & Heard, D. E. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35140d · Cited by 599
Liu, Y., & Wang, T. (2020) · Atmospheric Chemistry and Physics · doi:10.5194/acp-20-6323-2020 · Cited by 345
Metadata
- Authors
- Fuchs, H., Bohn, B., Hofzumahaus, A., Holland, F., Lu, K. D., Nehr, S., Rohrer, F., & Wahner, A.
- Venue
- Atmospheric Measurement Techniques
- Publisher
- Copernicus GmbH
- Published
- 2011-06-28
- Volume
- 4
- Issue
- 6
- Pages
- 1209-1225
- ISSN
- 1867-1381 (ISSN-L)
- 1867-8548
- OpenAlex
- W2137029702
- Cited by
- 194
- References
- 0
- FWCI
- 11.05
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of HO 2 by laser-induced fluorescence: calibration and interferences from RO 2 radicals. https://app.cochat.ai/papers/10.5194/amt-4-1209-2011
- The paper
- Fuchs, H., Bohn, B., Hofzumahaus, A., Holland, F., Lu, K. D., Nehr, S., Rohrer, F., & Wahner, A. (2011). Detection of HO 2 by laser-induced fluorescence: calibration and interferences from RO 2 radicals. Atmospheric Measurement Techniques. https://doi.org/10.5194/amt-4-1209-2011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.