The DOI matches its Crossref record.
Effective density of Aquadag and fullerene soot black carbon reference materials used for SP2 calibration
Open accessAbstract
The mass and effective density of black carbon (BC) particles generated from aqueous suspensions of Aquadag and fullerene soot was measured and parametrized as a function of their mobility diameter. The measurements were made by two independent research groups by operating a differential mobility analyser (DMA) in series with an aerosol particle mass analyser (APM) or a Couette centrifugal particle mass analyser (CPMA). Consistent and reproducible results were found in this study for different production lots of Aquadag, indicating that the effective density of these particles is a stable quantity and largely unaffected by differences in aerosol generation procedures and suspension treatments. The effective density of fullerene soot particles from one production lot was also found to be stable and independent of suspension treatments. Some differences to previous literature data were observed for both Aquadag and fullerene soot at larger particle diameters. Knowledge of the exact relationship between mobility diameter and particle mass is of great importance, as DMAs are commonly used to size-select particles from BC reference materials for calibration of single particle soot photometers (SP2), which quantitatively detect the BC mass in single particles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brownness of organics in aerosols from biomass burning linked to their black carbon content
Saleh, R., Robinson, E. S., Tkacik, D. S., Ahern, A. T., Liu, S., Aiken, A. C., Sullivan, R. C., Presto, A. A., Dubey, M. K., Yokelson, R. J., et al. (2014) · Nature Geoscience · doi:10.1038/ngeo2220 · Cited by 610
Lack, D. A., Moosmüller, H., McMeeking, G. R., Chakrabarty, R. K., & Baumgardner, D. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7402-3 · Cited by 269
The observed influence of local anthropogenic pollution on northern Alaskan cloud properties
Maahn, M., de Boer, G., Creamean, J. M., Feingold, G., McFarquhar, G. M., Wu, W., & Mei, F. (2017) · Atmospheric Chemistry and Physics · doi:10.5194/acp-17-14709-2017 · Cited by 32
“::: are ::::::::::: described ::: in ::::::: detail ::: by ::::::::::::::::::::::::: Gysel et al. (2011) and :::::::::::::::::::: Irwin et al. (2013). :::::: The”
Influential
Metadata
- Authors
- Gysel, M., Laborde, M., Olfert, J. S., Subramanian, R., & Gröhn, A. J.
- Venue
- Atmospheric Measurement Techniques
- Publisher
- Copernicus GmbH
- Published
- 2011-12-22
- Volume
- 4
- Issue
- 12
- Pages
- 2851-2858
- ISSN
- 1867-1381 (ISSN-L)
- 1867-8548
- OpenAlex
- W2128903528
- Cited by
- 174
- References
- 0
- FWCI
- 6.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effective density of Aquadag and fullerene soot black carbon reference materials used for SP2 calibration. https://app.cochat.ai/papers/10.5194/amt-4-2851-2011
- The paper
- Gysel, M., Laborde, M., Olfert, J. S., Subramanian, R., & Gröhn, A. J. (2011). Effective density of Aquadag and fullerene soot black carbon reference materials used for SP2 calibration. Atmospheric Measurement Techniques. https://doi.org/10.5194/amt-4-2851-2011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.