CoChat

Particle sizing calibration with refractive index correction for light scattering optical particle counters and impacts upon PCASP and CDP data collected during the Fennec campaign

Open access
Rosenberg, P. D., Dean, A. R., Williams, P. I., Dorsey, J. R., Minikin, A., Pickering, M. A., Petzold, A. · 2012 · Atmospheric Measurement Techniques

Published version of a preprint

The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.

Abstract

Optical particle counters (OPCs) are used regularly for atmospheric research, measuring particle scattering cross sections to generate particle size distribution histograms. This manuscript presents two methods for calibrating OPCs with case studies based on a Passive Cavity Aerosol Spectrometer Probe (PCASP) and a Cloud Droplet Probe (CDP), both of which are operated on the Facility for Airborne Atmospheric Measurements BAe-146 research aircraft. A probability density function based method is provided for modification of the OPC bin boundaries when the scattering properties of measured particles are different to those of the calibration particles due to differences in refractive index or shape. This method provides mean diameters and widths for OPC bins based upon Mie-Lorenz theory or any other particle scattering theory, without the need for smoothing, despite the highly nonlinear and non-monotonic relationship between particle size and scattering cross section. By calibrating an OPC in terms of its scattering cross section the optical properties correction can be applied with minimal information loss, and performing correction in this manner provides traceable and transparent uncertainty propagation throughout the whole process. Analysis of multiple calibrations has shown that for the PCASP the bin centres differ by up to 30% from the manufacturer's nominal values and can change by up to approximately 20% when routine maintenance is performed. The CDP has been found to be less sensitive than the manufacturer's specification with differences in sizing of between 1.6 ± 0.8 μm and 4.7 ± 1.8 μm for one flight. Over the course of the Fennec project in the Sahara the variability of calibration was less than the calibration uncertainty in 6 out of 7 calibrations performed. As would be expected from Mie-Lorenz theory, the impact of the refractive index corrections has been found to be largest for absorbing materials and the impact on Saharan dust measurements made as part of the Fennec project has been found to be up to a factor of 3 for the largest particles measured by CDP with diameters of approximately 120 μm. In an example case, using the calibration and refractive index corrections presented in this work allowed Saharan dust measurement from the PCASP, CDP and a Cloud Imaging Probe to agree within the uncertainty of the calibration. The agreement when using only the manufacturer's specification was poor. Software tools have been developed to perform these calibrations and corrections and are now available as open source resources for the community via the SourceForge repository.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5194/amt-5-1147-2012

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 175

Metadata

Authors
Rosenberg, P. D., Dean, A. R., Williams, P. I., Dorsey, J. R., Minikin, A., Pickering, M. A., & Petzold, A.
Affiliations
  • University of Leeds (GB)
  • University of Manchester (GB)
  • Deutsches Zentrum für Luft- und Raumfahrt e. V. (DLR) (DE)
  • Met Office (GB)
Venue
Atmospheric Measurement Techniques
Published
2012-05-21
Volume
5
Issue
5
Pages
1147-1163
ISSN
  • 1867-1381 (ISSN-L)
  • 1867-8548
OpenAlex
W2106839083
Cited by
154
References
35
Citations by year
2026: 3 · 2025: 7 · 2024: 7 · 2023: 14 · 2022: 15 · 2021: 37 · 2020: 7 · 2019: 8 · 2018: 13 · 2017: 7 · 2016: 19 · 2015: 5 · 2014: 3 · 2013: 3 · 2012: 6
FWCI
4.50
Type
journal article
Language
en
Open access
Locations
  • Atmospheric measurement techniques (publishedVersion, cc-by)
  • White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Research Explorer (The University of Manchester) (submittedVersion)
Funders
  • Met Office
  • Natural Environment Research Council (NE/G017166/, NE/G017166/1)
Topics
  • Physical Sciences › Environmental Science › Global and Planetary Change › Atmospheric aerosols and clouds
  • Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Atmospheric chemistry and aerosols
  • Physical Sciences › Engineering › Aerospace Engineering › Calibration and Measurement Techniques
Keywords
optical particle counter, refractive index correction, scattering cross section, Saharan dust, particle size distribution, error propagation, airborne aerosol measurements

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.