A fast and precise chemiluminescence ozone detector for eddy flux and airborne application
Open accessThe DOI matches its Crossref record.
Abstract
A commercially available dry chemiluminescence (CI) instrument for fast and precise measurement of ozone (O3) is specified. The sensitivity is ~9000 counts s−1 per ppbv of ozone. Its precision is entirely determined by the number of photons reaching the detector (being a photomultiplier), i.e. is quantum-noise limited. The relative precision (ΔO3/O3 in %) thus follows Poisson statistics and scales with the square root of the measurement frequency f and with the inverse O3 mixing ratio: ΔO3/O3 ∝ f0.5 · O3−0.5. At typical O3 mixing ratios between 10 and 100 ppbv (and 1 bar), the precision is 0.3–1.0% at f = 10 Hz. The maximum measurement frequency is 50 Hz. The mechanical and electronic set-up as well as the instrument performance is described. Recommendations on the adequate inlet tube configuration (inlet tube length, sampling flow) and on the way of calibration at stationary ground-based platforms and onboard aircraft are given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jöckel, P., Tost, H., Pozzer, A., Kunze, M., Kirner, O., Brenninkmeijer, C. A. M., Brinkop, S., Cai, D. S., Dyroff, C., Eckstein, J., et al. (2016) · Geoscientific Model Development · doi:10.5194/gmd-9-1153-2016 · Cited by 370
Self-citationPetzold, A., Thouret, V., Gerbig, C., Zahn, A., Brenninkmeijer, C. A. M., Gallagher, M., Hermann, M., Pontaud, M., Ziereis, H., Boulanger, D., et al. (2015) · Tellus B: Chemical and Physical Meteorology · doi:10.3402/tellusb.v67.28452 · Cited by 363
Self-citationVoigt, C., Schumann, U., Minikin, A., Abdelmonem, A., Afchine, A., Borrmann, S., Boettcher, M., Buchholz, B., Bugliaro, L., Costa, A., et al. (2017) · Bulletin of the American Meteorological Society · doi:10.1175/bams-d-15-00213.1 · Cited by 266
“…following trace gases were measured: reactive nitrogen species as aircraft tracer (Ziereis et al. 2000), ozone as tracer for photochemical production and stratospheric air (Zahn et al. 2012), as well as other tropospheric and stratospheric tracers (Prados-Roman et al. 2011; Weidner et al. 2005).”
BackgroundSelf-citationKeber, T., Bönisch, H., Hartick, C., Hauck, M., Lefrancois, F., Obersteiner, F., Ringsdorf, A., Schohl, N., Schuck, T., Hossaini, R., et al. (2020) · Atmospheric Chemistry and Physics · doi:10.5194/acp-20-4105-2020 · Cited by 57
Development of Technologies for Sensing Ozone in Ambient Air
Ando, M., Biju, V., & Shigeri, Y. (2018) · Analytical Sciences · doi:10.2116/analsci.34.263 · Cited by 32
Metadata
- Authors
- Zahn, A., Weppner, J., Widmann, H., Schlote-Holubek, K., Burger, B., Kühner, T., & Franke, H.
- Venue
- Atmospheric Measurement Techniques
- Publisher
- Copernicus GmbH
- Published
- 2012-02-15
- Volume
- 5
- Issue
- 2
- Pages
- 363-375
- ISSN
- 1867-1381 (ISSN-L)
- 1867-8548
- OpenAlex
- W2126098648
- Cited by
- 157
- References
- 0
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.