The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Calibrated high-precision 17 O-excess measurements using cavity ring-down spectroscopy with laser-current-tuned cavity resonance
Open accessAbstract
High-precision analysis of the 17O / 16O isotope ratio in water and water vapor is of interest in hydrological, paleoclimate, and atmospheric science applications. Of specific interest is the parameter 17O excess (Δ17O), a measure of the deviation from a~linear relationship between 17O / 16O and 18O / 16O ratios. Conventional analyses of Δ17O of water are obtained by fluorination of H2O to O2 that is analyzed by dual-inlet isotope ratio mass spectrometry (IRMS). We describe a new laser spectroscopy instrument for high-precision Δ17O measurements. The new instrument uses cavity ring-down spectroscopy (CRDS) with laser-current-tuned cavity resonance to achieve reduced measurement drift compared with previous-generation instruments. Liquid water and water-vapor samples can be analyzed with a better than 8 per meg precision for Δ17O using integration times of less than 30 min. Calibration with respect to accepted water standards demonstrates that both the precision and the accuracy of Δ17O are competitive with conventional IRMS methods. The new instrument also achieves simultaneous analysis of δ18O, Δ17O and δD with precision of < 0.03‰, < 0.02 and < 0.2‰, respectively, based on repeated calibrated measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Craig, H. (1957) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(57)90024-8 · Cited by 4,170 · cited 1×
“…the fractionation factor forδ17O between two different phases will be approximately the square root of the fractionation factor forδ18O (Urey, 1947; Craig, 1957; Mook, 2000): 17Ra 17Rb = ( 18Ra 18Rb )λ , (3) whereλ = 0.5010–0.5305 (Kaiser, 2008) and the subscripts “a” and “b” refer to different…”
BackgroundInfluentialThe thermodynamic properties of isotopic substances
Urey, H. C. (1947) · Journal of the Chemical Society (Resumed) · doi:10.1039/jr9470000562 · Cited by 2,544
Cited by
Stable isotopes in atmospheric water vapor and applications to the hydrologic cycle
Galewsky, J., Steen‐Larsen, H. C., Field, R. D., Worden, J., Risi, C., & Schneider, M. (2016) · Reviews of Geophysics · doi:10.1002/2015rg000512 · Cited by 489
A stable isotope toolbox for water and inorganic carbon cycle studies
Hillaire-Marcel, C., Kim, S.-T., Landais, A., Ghosh, P., Assonov, S., Lécuyer, C., Blanchard, M., Meijer, H. A. J., & Steen-Larsen, H. C. (2021) · Nature Reviews Earth & Environment · doi:10.1038/s43017-021-00209-0 · Cited by 43
Saenger, C. P., Schauer, A. J., Heitmann, E. O., Huntington, K. W., & Steig, E. J. (2021) · Chemical Geology · doi:10.1016/j.chemgeo.2021.120059 · Cited by 11
Self-citation
Metadata
- Authors
- Steig, E. J., Gkinis, V., Schauer, A. J., Schoenemann, S. W., Samek, K., Hoffnagle, J., Dennis, K. J., & Tan, S. M.
- Venue
- Atmospheric Measurement Techniques
- Publisher
- Copernicus GmbH
- Published
- 2014-08-08
- Volume
- 7
- Issue
- 8
- Pages
- 2421-2435
- ISSN
- 1867-1381 (ISSN-L)
- 1867-8548
- OpenAlex
- W2162911290
- Cited by
- 170
- References
- 2
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibrated high-precision 17 O-excess measurements using cavity ring-down spectroscopy with laser-current-tuned cavity resonance. https://app.cochat.ai/papers/10.5194/amt-7-2421-2014
- The paper
- Steig, E. J., Gkinis, V., Schauer, A. J., Schoenemann, S. W., Samek, K., Hoffnagle, J., Dennis, K. J., & Tan, S. M. (2014). Calibrated high-precision 17 O-excess measurements using cavity ring-down spectroscopy with laser-current-tuned cavity resonance. Atmospheric Measurement Techniques. https://doi.org/10.5194/amt-7-2421-2014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.