Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 192

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Validation and application of a cryogenic vacuum extraction system for soil and plant water extraction for isotope analysis

Open access
Orlowski, N., Frede, H.-G., Brüggemann, N., Breuer, L.·2013·Journal of Sensors and Sensor Systems

Abstract

Abstract. Stable isotopic analysis of water in plant, soil, and hydrological studies often requires the extraction of water from plant or soil samples. Cryogenic vacuum extraction is one of the most widely used and accurate extraction methods to obtain such water samples. Here, we present a new design of a cryogenic vacuum extraction system with 18 extraction slots and an innovative mechanism to aerate the vacuum system after extraction. This mobile and extendable multi-port extraction system overcomes the bottleneck of time required for capturing unfractionated extracted water samples by providing the possibility to extract a larger number of samples per day simultaneously. The aeration system prevents the loss or mixture of water vapor during defrosting by purging every sample with high-purity nitrogen gas. A set of system functionality tests revealed that the extraction device guarantees stable extraction conditions with no changes in the isotopic composition of the extracted water samples. Surprisingly, extractions of dried and rehydrated soils showed significant differences of the isotopic composition of the added water and the extracts. This observation challenges the assumption that cryogenic extraction systems to fully extract soil water. Furthermore, in a plant water uptake study different results for hydrogen and oxygen isotope data were obtained, raising problems in the definition from which depths plants really take up water. Results query whether the well-established and widely used cryogenic vacuum distillation method can be used in a standard unified method of fixed extraction times as it is often done.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.5194/jsss-2-179-2013

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 192

Metadata

Authors
Orlowski, N., Frede, H.-G., Brüggemann, N., & Breuer, L.
Venue
Journal of Sensors and Sensor Systems
Published
2013-11-13
Volume
2
Issue
2
Pages
179-193
ISSN
  • 2194-8771 (ISSN-L)
  • 2194-878X
OpenAlex
W2161221270
Cited by
192
References
1
FWCI
9.55
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation and application of a cryogenic vacuum extraction system for soil and plant water extraction for isotope analysis. https://app.cochat.ai/papers/10.5194/jsss-2-179-2013
The paper
Orlowski, N., Frede, H.-G., Brüggemann, N., & Breuer, L. (2013). Validation and application of a cryogenic vacuum extraction system for soil and plant water extraction for isotope analysis. Journal of Sensors and Sensor Systems. https://doi.org/10.5194/jsss-2-179-2013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.